Skip to content

Work it out.

Calculators

23

Subnet calculator (IPv4)

IPv4 / CIDR notation

Transfer time

Bandwidth

RAID capacity and fault tolerance

RAID-lagerteknologi (branchestandard, jf. SNIA Common RAID Disk Data Format)

UPS battery time (runtime)

Grundlæggende UPS-runtime-fysik (branchepraksis, jf. APC/Eaton runtime-kalkulatorer)

PoE power budget for switch

IEEE 802.3af/at/bt (Power over Ethernet-standarder)

Copper cabling — margin to the 100 m channel limit

TIA/EIA-568 kabling-standard (100 m maks. kanallængde for kobber-Ethernet)

Fibre-optic loss budget (dB)

ITU-T G.652 (fiberdæmpning) + TIA-568.3-D (typiske konnektor-/splejsningstab)

Wi-Fi — realistic throughput

Branchepraksis for 802.11-protokoloverhead (Cisco/Ubiquiti trådløs designvejledning: typisk 50-60% af PHY-raten)

VoIP bandwidth per simultaneous call

Ciscos VoIP-båndbreddetabel, Doc ID 7934 (codec-payload + IP/UDP/RTP-overhead, 20 ms-pakketisering)

Delay budget for voice/video (ITU-T G.114)

ITU-T G.114 (anbefalet maks. 150 ms ende-til-ende-forsinkelse, ≤400 ms accepteret grænse)

Backup storage requirement (3-2-1 rule)

3-2-1-backupreglen (CISA/US-CERT-anbefaling: mindst 3 kopier af data, på 2 forskellige medietyper, 1 kopi offsite)

Helpdesk/service desk capacity

Grundlæggende kapacitetsberegning (ITIL 4 Service Desk-praksis: tilgængelig tid ÷ gennemsnitlig håndteringstid)

Subnetting: number of subnets when borrowing bits

RFC 4632 (CIDR — Classless Inter-Domain Routing, IETF)

Disk capacity — GB (manufacturer) vs. GiB (operating system)

IEC 60027-2 / IEC 80000-13 (binære præfikser: GiB = 2³⁰ bytes, mod decimale SI-præfikser: GB = 10⁹ bytes)

Switch — uplink oversubscription ratio

Cisco campus-netværksdesign — oversubscription højst ca. 20:1 fra adgangslaget og ca. 4:1 fra distributionslaget

Memory usage for a data structure

IEEE 754 (flydende decimal-standard) + almindelige programmeringssprogs heltalsstørrelser

SIEM: log store based on events per second

Log management sizing (EPS × byte × time) · competence objective on SIEM and log management

Quantitative risk assessment (SLE, ARO, ALE)

Quantitative risk analysis: SLE = value × EF, ALE = SLE × ARO (ISC² CISSP CBK; risk = likelihood × consequence, NIST SP 800-30)

Availability from MTBF and MTTR, with redundancy

Availability A = MTBF ÷ (MTBF + MTTR) · parallel redundancy 1 − (1 − A)ⁿ (ITIL Availability Management, IEC 60050-192)

Server room: heat load, cooling and electricity per year

Energy balance: 1 W = 3.412 BTU/h · PUE = total power ÷ IT power (The Green Grid)

Bent bracket

Exact flat pattern

Edge-bent panel

Exact flat pattern

Cable tray

Exact flat pattern

Tools that work in all subjects

Across trades