Control form: Periodic inspection of cables and chains
Disposal criteria for use in inspection of lifting equipment
§Steel wire — discarded at
Control point
Discarded if
Wire break
Number of visible breaks over the limit within a given wire length
Diameter
Outer diameter is noticeably reduced compared to original
Shape
Bird's nest effect, kink, pinching or flayed ends
Corrosion / heat
Visible wear of wires, or signs of heat exposure
§PLACEHOLDER_92
Control point
Discarded if
Extension
Measured length exceeding the limit manufacturer specifies (elongation)
Led
Deformed steel has lost load-bearing capacity, even when it looks straight after straightening. The standard's principle is replacement, not straightening.
Heat exposure
Discolouration or other signs that the chain has been exposed to high heat