Technical insulation — from craftsmanship to standard

How Danish insulation trade grew from experience to standard

2026-06-24·7 min reading

Technical insulation has developed from an experience-based craft to a documented, standard-based discipline. Here we follow the tracks that can be documented: the energy crisis of the 1970s, Danish insulation standards from DS 325 to DS 452, the emergence of condensation insulation with refrigeration technology, and today's focus on precision calculation and sustainability.

Introduction

Technical insulation is one of the trades where the profession and its regulatory basis have developed closely together. Today, an insulator works according to standards, material data sheets, and calculated thicknesses — but the discipline began as an experience-based trade where people wrapped hot pipes to save energy and keep surfaces safe to touch. This article sticks to the part of the story that can be documented in standards, legislation, and the profession's own teaching materials.

A craft of experience becomes a craft of calculation

The need for technical insulation follows with steam power, industry and later central heating: hot pipes lose energy, and cold pipes collect condensation. For a long time dimensioning was largely experience-based — one insulated based on practice and rules of thumb rather than calculated limits. What really changed the profession was not a new material, but the requirement to be able to put numbers on heat loss.

Energy crisis and the first Danish requirements (1970s)

The 1973 oil crisis and subsequent energy price increases made heat loss an economic and political issue in Denmark. Energy saving was put into system, and technical insulation went from being a convenience to being a measurable contribution to reducing energy consumption. It is in this light that the Danish insulation standards should be understood: they translate a desire for less heat loss into concrete, controllable requirements.

Fra DS 325 til DS 452

Denmark got a proper standard for thermal insulation of technical installations which over time has been revised. The current version is DS 452:2013 which came into force on 31 May 2014. Where earlier versions to a greater extent worked with allowed heat flows DS 452 is based on a system of energy classes (class 1–6) where each class corresponds to a maximum allowed heat loss per m² outer surface. This makes it possible to set a clear requirement — a class — and then calculate the thickness that meets it on a specific pipe.

  • 01DS 452:2013 — the current Danish standard for thermal insulation of technical systems.
  • 02Energy classes (class 1–6) — requirements expressed as max. heat loss per m² of external surface at a given temperature difference.
  • 03EN ISO 12241 — the European calculation method for heat loss from cylindrical, insulated surfaces, which the dimensioning is based on.
  • 04BR18 — the Building Regulations refers to the relevant standards for installations, including fire safety requirements.

The rest of the article is locked

Create a free user account to unlock all articles, calculators, templates and range — and get access to quizzes and classes. It takes less than a minute: name, email and a password. No payment card.

Want to try something first? See what you can use without an account — the junior zone, the encyclopedia, the videos and more.