QA is mandatory for all load-bearing and climate-screening work. Here is the three-phase model from DI Building, what is checked when, and why photo documentation of hidden structures is crucial.
Introduction
Quality assurance (QA) of load-bearing and climate-envelope structures is mandatory under BR18 chapter 35. It is not just paperwork — it is the systematic inspection that ensures the structure is built as the project requires and that errors are detected before they are hidden behind cladding and plaster.
Three control phases
| Phase | DI Byggeri form | What is checked? |
|---|---|---|
| Receiving inspection | Form 2 | Deliveries: dimensions, color, CE marking, moisture content |
| Process control | Form 3 | Joints, vapour barrier tightness, insulation thickness, fittings |
| Final check | Form 9 | Finished work against drawing and agreement |
The standard templates have been published by DI Construction in »KS manual for masons, carpenters, and floor layers«. The manual also contains inspection plan, organizational plan, and documentation list – available via haandvaerker.dk and danskindustri.dk.
Receiving inspection
When structural timber is delivered, the carpenter must verify: correct dimensions and grading quality, CE marking and strength grading certificate (DS/EN 14081-1—mandatory for load-bearing timber), moisture content (typically 12% ± 3% for delivery—measure with moisture meter), and that the shipment matches the project. Deviations are noted in form 2 and the supplier is contacted.
Members only
The rest of the article is locked
Create a free user account to unlock all articles, calculators, templates and range — and get access to quizzes and classes. It takes less than a minute: name, email and a password. No payment card.