Vent cowl

Chinese hat, pyramid hat or rain cowl on a pipe spigot and struts — driven by the free opening area in the gap.

Exact flat patternLitre-drivenOutside dimensions29 dimensions8 presets
Vvs energi · Teknisk isolatoer …
Plumbing · Insulation · Carpenter …
exhaust hood · kineserhat …
exhaust hood · kineserhat · kinamandshat · regnhat · regnhætte · aftrækshætte · vindhætte · deflektor · deflektorhætte · pyramidehat · firkanthætte · kanalhætte · afkastshætte · tagudluftning · udluftningshat

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

29 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Hood typehattypeKineserhat (rund kegle) · Pyramidehat (firkantet) · Vindhætte/deflektor (to kegler)Kineserhat (rund kegle)—
Pipe nozzle diameter (outside)conditionalroer_D50–1.200 mm · step size 1200 mmThe spigot's FINISHED outside dimension. It must be able to go down over the flue — include the play in the figure yourself.
Long side of the duct (outside)conditionalkanal_a50–1.200 mm · step size 1300 mmOutside dimension of the nozzle. The cap's base line becomes this plus 2 × the overhang.
Short side of the duct (outside)conditionalkanal_b50–1.200 mm · step size 1200 mmThe seam is placed in the middle of this side, so both long sides remain unbroken.
Cap overhangdriveroverhaeng10–300 mm · step size 550 mmHow far the cap projects beyond the outside of the pipe. At least equal to the gap height, otherwise driving rain gets in.
Slope of the cap from horizontalhaeldning10–60 ° · step size 130 °Below 15° the water does not run off on its own. For the pyramid cap the figure applies to the FLATTEST of the four faces.
Gap height at the cap's bottom edgedriverspaltehoejde10–300 mm · step size 545 mmVertically from the top of the pipe up to the OUTERMOST edge of the cap. The clearance above the pipe wall is greater — it is shown as a key figure.
Slope of the lower coneconditionaldeflektor_haeldning10–60 ° · step size 130 °The inverted cone below the pipe's top edge. It catches driving rain and sheds it — and doesn't make the gap smaller.
Pipe nozzle heightskoert_hoejde30–600 mm · step size 5120 mmThe spigot must be tall enough for the stiffener's rivet foot and to close tightly round the flue.
Number of spacer stiffenersconditionalantal_stivere3–6 stk · step size 13 stkThree is the minimum for a stable three-leg suspension. The square cap is always supported at the four corners.
Stiffener strip widthstiverprofilStrip 20 mm wide · Strip 25 mm wide · Strip 30 mm wide · Strip 40 mm wideStrip 25 mm wide—
The stiffener's rivet foot on the spigotstiver_fod20–150 mm · step size 540 mmThe part of the stiffener that lies below the pipe's top edge and carries the two rivets.
The stiffener's top flange under the capstiver_flange15–120 mm · step size 530 mmMust not be longer than the sloping side under the cap (overhang / cos pitch) — see the warning.
Insect mesh in the gapinsektneton / offoffThe mesh is clamped with a strip. It takes up part of the free area — the figure is calculated.
Mesh aperture (clear opening)conditionalnet_maske0,5–10 mm · step size 0,11,6 mmThe opening between the wires. Together with the wire diameter, it gives the mesh's geometric open area.
Mesh wire diameterconditionalnet_traad0,2–2 mm · step size 0,050,4 mmGiven on the mesh data sheet. Open area = (mesh/(mesh + wire))².
Outer edge of the capconditionalkant_hatRå kant · Sik (smal opkant) · Ombuk 90°Sik (smal opkant)The pyramid cap's triangles are flat faces without a canonical edge position — so the field applies only to the round caps.
Measure at the cap's outer edgeconditionalkant_hat_mm3–40 mm · step size 16 mmHems and fold-overs are measured on the OUTSIDE — the beading wheel's dimension, not the flat leg on the blank.
The nailssoemtypeButt-welded · Riveted overlap · Punktsvejst overlæg · Lock-seamedRiveted overlapApplies to the wedge seam of the cap, the longitudinal seam of the nozzle and the seam of the clamping ring.
Overlap widthconditionalsoem_overlaeg0–60 mm · step size 520 mm0 = the workshop's own rule (BAI: 20/35/50 mm by finished Ø). The lap is placed on ONE part.
AlloyinglegeringHot-dip galvanised steel sheet DX51D+Z · Aluminium AlMg3 (5754) · Aluminium, pure (1050A) · Copper Cu-DHP · Titanium zinc (roofing zinc) · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316L · Structural steel S235JRHot-dip galvanised steel sheet DX51D+ZThe designation goes on the delivery note and sets the density in the weight — the family name is not enough.
Goods thicknesst_mm0,5–2 mm · step size 0,051 mmUsed for the neutral axis, edge allowance and weight. A hood is rarely made in more than 1.5 mm.

Advanced fields

7

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Stiffener material thicknessstiver_t0–3 mm · step size 0,10 mm0 = same sheet as the hat. Enter a value if the stiffener is to be cut from thicker material.
Clamping ring heightconditionalnet_baand10–60 mm · step size 525 mmThe strip that clamps the mesh against the cap's edge.
Root gap in the butt seamconditionalrodaabning0–4 mm · step size 0,51 mmSubtracted from the circumference, half on each edge. Forgetting 2 mm gives a diameter 0.64 mm too large.
Seam width Wconditionalfals_W4–20 mm · step size 18 mmTotal material consumption is 3·W, split with half on each part — net 2·W on the circumference.
Blind rivet diameternitte_mmØ3.2 mm (hole Ø3.3) · Ø4.0 mm (hole Ø4.1) · Ø4.8 mm (hole Ø4.9)Ø4.0 mm (hole Ø4.1)—
Velocity in the gaplufthastighed0,5–15 m/s · step size 0,52 m/sAn INPUT from the project — it is in the ventilation calculation. The starting value is only a starting point, not a recommendation.
Number of identical hoodsantal1–200 stk · step size 11 stkIncluded in the parts list and weight. The sheet plan nests by the workshop's «quantity».

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Chinese hat Ø125 (bathroom ventilation)

Gap 35 mm versus 35 mm overhang — exactly 45°, and the free area is 1.8 × the pipe's cross-section

Also known as: kineserhat · regnhat · kinamandshat · exhaust hood · aftrækshætte · tagudluftning

Chinese hat Ø200 with insect mesh

The 1.6/0.4 mm mesh lets 64 % through — the free area drops from 595 to 381 cm²

Also known as: insektnet · myggenet · regnhat med net · kineserhat · fluenet · aftrækshætte

Chinese hat Ø400 over a ventilation outlet

Ø400 with 100 mm overhang: 35° cap, slant side 365.5 mm — the blank is a 731 mm disc

Also known as: afkastshætte · kineserhat · ventilationshætte · afkast · udblæsningshætte · regnhat

Wind cowl Ø160 (deflector with two cones)

The inverted cone has the same Ø as the hat — it catches driving rain without making the gap smaller

Also known as: vindhætte · deflektor · deflektorhætte · rotationsfri hætte · vindsuger · aftrækshætte

Pyramid cap over a 300 × 200 rectangular duct

The shallowest face is the selected 30°; the other becomes 37.2°, because the duct isn't square

Also known as: pyramidehat · firkantet hætte · kanalhætte · firkanthætte · kassehætte · exhaust hood

Pyramid cap 400 × 400 (square duct)

Square base: all four faces are the same 30°, and all four triangles are the same workpiece

Also known as: pyramidehat · kvadratisk hætte · firkanthætte · kanalhætte · pyramidetop · tagudluftning

Sheet-metal cap over an insulated flue DN100 + 50 mm

Ø214.3 = the bare pipe 114.3 plus 2 × 50 mm insulation — the cap sits on the CLADDING, not on the pipe

Also known as: blikhætte · isoleringshætte · kappehætte · aftrækshætte · insulation · regnhat

Hood Ø630 over a stable extract

Ø630 with 150 mm overhang and 120 mm gap: 3,506 cm² open area versus the pipe's 3,088 cm²

Also known as: staldudsugning · udsugningshætte · stor hætte · afkastshætte · agriculture · ventilationshætte

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • Wind load, snow load and anchoring are NOT covered. A hood on a roof is a wind-exposed building component and must be verified in accordance with EN 1991-1-4 and EN 1991-1-3. The tool sizes neither stiffeners, rivets nor hangers — it draws them.
  • Chimney and flue systems are CERTIFIED equipment (EN 1856-1/-2). A cowl on a combustion flue changes the draught and must not be manufactured according to this figure; use the manufacturer's approved cowl.
  • ‘Free area at least equal to the pipe's cross-section’ is a RULE OF PRACTICE, not a standard. The actual pressure loss depends on the outlet loss and on the shape of the cowl, and neither pressure loss nor k-value is calculated here. The leakage class in a connected duct follows EN 12237 and is likewise not covered.
  • The insect screen's free-area proportion is PURE GEOMETRY: (mesh/(mesh + wire))². The screen's actual resistance coefficient is given on the data sheet — the tool does not invent it, and a clogged screen has no free area.
  • Water penetration is tested to a standard method in accordance with EN 13030. The 45° rule ‘overhang ≥ gap height’ is the workshop's rule of thumb and says nothing about driving rain at high wind speed.
  • The riveting rules (edge distance 2 × Ø, strap width 4 × Ø, pitch at most 8 × Ø) are workshop practice from the blind-rivet suppliers' installation instructions — NOT a standard. Only the hole Ø is standard-backed (DIN 7337 / ISO 15977).
  • The K-factor is DIN 6935's suggestion and is NOT standard-backed for stainless steel, aluminium, copper and titanium zinc. Check the stiffener's bend deduction against a trial bend in the material you are using.
  • Galvanic corrosion between materials is not addressed. A copper hood above a galvanised flue will destroy the zinc; the combination must be chosen deliberately and kept separated.