Nozzle with tab collar on a flat wall
Rundt stuts i plan kanalvæg: fligekraven med spalte, tøjning og nitter — plus hullet i væggen.
How true is the flat pattern?
The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.
Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
21 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Studsens udvendige Ødriverstuds_d | 63–630 mm · step size 1 | 160 mm | Ydermålet — det spirorøret hedder. Handelsstørrelserne er 63 · 80 · 100 · 125 · 160 · 200 · 250 · 315 · 400 · 500 · 630 mm; andre mål skal bekræftes hos leverandøren. |
| Goods thicknesst | 0,5–1,2 mm · step size 0,05 | 0,6 mm | Hvilken tykkelse en given kanaldel KRÆVER står i DS 447 / EN 1506 — det er et input her. |
| Fri studslængde over væggenstuds_laengde | 30–1.000 mm · step size 5 | 150 mm | Fladt blanketmål fra snitlinjen og op til rørets frie ende. Ved skråt stuts er det den KORTESTE generatrix; den længste bliver 2·R_n·cot θ længere. |
| Vinkel mellem studs og kanalvægtheta | 30–90 ° · step size 1 | 90 ° | 90° = vinkelret på væggen ⇒ rundt hul. Under 90° bliver hullet en ellipse med lang akse D/sin θ. |
| Sådan sidder stutsen i væggenmontage | Set-in — stutsen stikkes ind gennem hullet · Set-on — stutsen sidder på væggen over hullet | Set-in — stutsen stikkes ind gennem hullet | Valget ændrer huldiameteren med 2·t + spillerum — det er ikke en teknikalitet. |
| Spillerum i hulletconditionalspillerum | 0–3 mm · step size 0,5 | 1 mm | Luften mellem rørets yderside og hullets kant, så stutsen kan komme i uden at binde. |
| Kravebredde (fligelængde)kravebredde | 10–40 mm · step size 1 | 25 mm | Fladt blanketmål fra snitlinjen. Kraven koster 2π·ℓ mm åbning ved fligespidserne — uanset hvor mange flige der er. |
| Værktøjet vælger antal fligeflige_auto | on / off | on | Sigter mod 30 mm fligebredde ved roden og mindst 10 flige, så fligen kan flades ud. |
| Antal fligeconditionalflige_antal | 6–48 stk · step size 1 | 16 stk | For få giver spalter der ikke kan tætnes; for mange er uarbejdeligt med tangen. |
| Spaltebredde mellem fligenespalte | 1–5 mm · step size 0,5 | 2 mm | Bredden af selve klippesnittet. Den skal mindst være maskinens snitbredde. |
| Fligens formfligeform | Lige flige (parallelle snit) · Kileformede flige (smallest ved roden) | Lige flige (parallelle snit) | — |
| Securingfastgoerelse | Popnitter (blindnitter) · Pladeskruer | Popnitter (blindnitter) | — |
| Tætningsliste under kraventaetningsliste | on / off | on | Kraven har spalter og er ikke tæt af sig selv. Listen kommer med i styklistens længdemål. |
| Modflange (rosette)rosette | on / off | off | Plan ring der spændes ned over fligene, så spidserne holdes plant og spalterne dækkes. |
| Rosettens rand uden for fligespidserneconditionalrosette_rand | 5–60 mm · step size 1 | 15 mm | — |
| Tegn vægudsnittet med hulletvaegudsnit | on / off | on | Findes kanalen allerede, bruges panelet som skabelon — rids hullet af og klip. |
| Alloyinglegering | Varmforzinket DX51D+Z (spiro/ventilation) · Rustfrit 1.4301 / AISI 304 · Rustfrit 1.4404 / AISI 316L · Aluminium AlMg3 (5754) · Koldvalset sort stål DC01 | Varmforzinket DX51D+Z (spiro/ventilation) | — |
Advanced fields
Hidden by default — they have a sensible default, and most parts do not need them.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Nitte-/skrue-Øfastgoerelse_d | 3–6,4 mm · step size 0,2 | 4 mm | — |
| Antal fastgørelser (0 = én pr. flig)fastgoerelser | 0–48 stk · step size 1 | 0 stk | En flig uden nitte løfter sig fra væggen. Færre end én pr. flig er et bevidst valg. |
| Vægudsnittets margen uden om kravenconditionalvaeg_margen | 20–300 mm · step size 5 | 60 mm | — |
| Lufthastighed i stutsenlufthastighed | 1–15 m/s · step size 0,5 | 4 m/s | Bruges til q = A·v gennem lysningen. Hastigheden er et INPUT fra projektet — grænserne for lyd og tryktab står i DS 447, ikke her. |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Tilslutningsstuds Ø160 i firkantkanal
17 flige à 29,5 mm deling, 25 mm krave — spalten vifter fra 2,0 til 11,2 mm
Also known as: tilslutningsstuds · spirostuds · stuts · afgreningsstuds · kanalstuds
Afkaststuds til 250 m³/h ved 4 m/s
Luftmængden driver diameteren: A = q/v = 17.361 mm² ⇒ lysning Ø148,7 mm
Also known as: afkast · udsugningsstuds · luftmængde · m3/h · dimensionering
Ø315 hovedafgang med rosette
33 flige, skruet, plan modflange 15 mm uden for fligespidserne
Also known as: hovedafgang · stor studs · rosettestuds · modflange · kravestuds
Skråt stuts 45° i kanalside
Hullet bliver en ellipse 202 × 284,8 mm, og ε_maks stiger med faktoren √2 til 35,5 %
Also known as: skråstuds · 45 grader · skrå afgrening · skævt studs · vinkelstuds
Ø125 emhætte-tilslutning i topplade
Lille studs, 20 mm krave og Ø3,2 nitter — 13 flige à 30,1 mm
Also known as: emhætte · køkkenaftræk · tilslutning · topplade · aftræksstuds
Ø200 med kileformede flige
Kilen halverer rodbuens flademangel — spalten ved spidsen er den samme
Also known as: kileflig · kilekrave · trapezflig · fligekrave · tungekrave
Ø160 rustfri i storkøkken-aftræk
1.4301 i 0,8 mm, set-on så der ikke står gods i fedtstrømmen
Also known as: storkøkken · rustfri studs · fedtaftræk · emfang · 1.4301
Ø500 hovedstuds i aggregatkanal
48 flige — blanketten er 1.568 mm bred, så røret købes som spiro
Also known as: hovedstuds · aggregat · stor spiro · hovedkanal · ventilationsaggregat
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- Figuren dimensionerer ikke kanalen. Hvilken godstykkelse, hvilken afstivning og hvilken tæthedsklasse en given kanalside kræver står i DS 447 og EN 1505/EN 1507 — det er et input her.
- Tæthed er ikke geometri. En fligekrave har pr. definition åbne spalter ved fligespidserne, og tæthedsklassen efter EN 12237 (runde kanaler) skal opnås med tætningsliste, mastik eller tape og dokumenteres ved prøvning.
- Fastgørelsens BÆREEVNE er ikke regnet. Nitte- og skrueafstandene (kantafstand ≥ 2·Ø, deling ≤ 8·Ø) er vejledende værkstedspraksis fra blindnitteleverandørernes montagevejledninger — ikke en standard. Kun hul-Ø er standardbelagt (DIN 7337 / ISO 15977).
- Brandspjæld og brandsikrede gennemføringer er IKKE dækket. Et spjæld i en brandcelleadskillelse er certificeret udstyr efter EN 15650 og må ikke monteres efter denne figur.
- Handelsserien 63–630 mm er en VEJLEDENDE lagerliste. De nominelle diametre for runde pladekanaler står i EN 1506; hvad der ligger på lager, står hos leverandøren — værktøjet opfinder det ikke.
- Lufthastigheden er et input. Grænserne for lyd, tryktab og balancering hører til ventilationsprojektet (DS 447) og er ikke i figuren.
- Stutsens frie ende leveres uden kanttillæg. En sik eller opkravning på en rund rand er strækning (ε = b/R_n) og ikke bukning — kantpressens bukketillæg gælder ikke der, og over 5 % kan kanten ikke formes hel.
- Isolering og dampspærre om stutsen er ikke i figuren. En kold kanal skal have gennemgående dampspærre ved gennemføringen, og det hører til isoleringsfaget.
Onward from here
- Cylinder – pladelængde til krop Metal worker
- Udfoldet længde ved bukning Metal fabricator
- Pladeudfoldning med K-faktor Technical designer
- Klinknagle – deling og kantafstand Metal worker
- Emner pr. plade (laserskæring) Technical designer
- The box unfolder A whole box unfolded with dimensions on every side — the same bending maths.
- 3D-workshop All the platform's 3D figures, including those without a flat pattern.
- The whole library Every figure, grouped and searchable by the words you know them under.