Skip to content

Tub with fall and drain

Rectangular tub with a horizontal rim and a floor that falls towards one drain: driven by litres, with a parallelogram floor, elliptical drain hole and dipping table.

Exact flat patternLitre-drivenInside dimensions26 dimensions8 presets
Smed · Metalsmed …
kar · kar med fald · vaskekar …
kar · kar med fald · vaskekar · skyllekar · shoulder bath · mejerikar · gulvkar · opsamlingskar · drypbakke · dryppebakke · spill tray · foderkar · trug · bassin · afløbskar · sump

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

26 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Hygienic zonehygiejneAs the workshop setting · Yes — food/drinking water · No — technical vesselAs the workshop settingA template cannot set the workshop's context, so the hygiene condition is a field on the figure. ‘As the workshop's setting’ follows the engine context.
Bottom fallfaldtypeFald mod den ene endevæg · Fald mod ét hjørne — én plan bund · Fald mod ét hjørne — bunden delt i to trekanter · Fald mod ét hjørne — én snoet bundpladeFald mod den ene endevæg—
Length (clear dimension)driverlaengde200–4.000 mm · step size 101.200 mm—
Width (clear dimension)driverbredde200–2.000 mm · step size 10800 mm—
Depth at the draindriverdybde_afloeb20–1.000 mm · step size 5250 mmThe deepest point of the tank, measured from the top of the rim to the top of the bottom plate.
Depth at the opposite end walldybde_ende5–1.000 mm · step size 5180 mmMust be less than the depth at the drain — otherwise the water runs the wrong way.
Depth at the opposite side wallconditionaldybde_side5–1.000 mm · step size 5200 mmThe cross fall. Without it the trough has a horizontal low line along the deep end wall.
Depth in the opposite cornerconditionaldybde_fjern5–1.000 mm · step size 5140 mmSet it to ‘depth_end + depth_side − depth_drain’, and the bottom is flat. Anything else is a TWIST — and a twist can either be split into two triangles or twisted in one sheet.
Goods thicknesst_mm0,8–4 mm · step size 0,11,5 mm1.5 mm for bench sinks, 2–3 mm for floor tanks and scalding tanks that get traffic.
MateriallegeringStainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316L · Hot-dip galvanised steel sheet DX51D+Z · Black steel S235JR (painted/coated)Stainless 1.4301 / AISI 304—
Vertical cornershjoernetypeStumpsvejst hjørne (langvæggen går udenom) · Geret og svejst hjørne · Overlappet hjørne (nittet/punktsvejst)Stumpsvejst hjørne (langvæggen går udenom)—
Overlap fasteningconditionaloverlaeg_fastBlind rivets · Spot welding · BoltsBlind rivets—
The rim at the toprandtypeRå skåret rand (slebet) · Opkant (bukket rand) · Ombukket rand (180°) · Vandret flange (til låg eller ramme)Opkant (bukket rand)—
Rim dimension (outside)conditionalrand_mm3–60 mm · step size 112 mm—
Drain positionafloeb_placeringMidt på den dybe endevæg · I hjørnet (afstand fra begge vægge)Midt på den dybe endevæg—
Drain — distance from the deep end wallafloeb_x30–2.000 mm · step size 5120 mm—
Drain — distance from the drain sideconditionalafloeb_y30–1.000 mm · step size 5120 mm—
Drain bore (internal Ø)studs_d25–110 mm · step size 150 mmThe clear bore, not the pipe's outside dimension — the figure calculates internally. The outside dimension becomes Ø + 2 · t.
Nozzle length (0 = hole only)studs_laengde0–400 mm · step size 590 mmThe dead-leg rule: at most 2 · the bore in a food zone.
Nozzle directionstuds_retningLodret (i lod — hullet bliver en ELLIPSE) · Vinkelret på bunden (hullet bliver en cirkel)Lodret (i lod — hullet bliver en ELLIPSE)—

Advanced fields

6

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Number of tanksantal1–50 stk · step size 11 stk—
Root gap in butt seamsrodaabning0–3 mm · step size 0,11 mmSubtracted FROM the blank (flat = −root gap). Applies to both the corner seams and the nozzle's longitudinal seam.
Overlap (0 = the edge allowance rule)conditionaloverlaeg_mm0–40 mm · step size 10 mm—
Flange angleconditionalrand_vinkel60–180 ° · step size 590 °—
Foot strip under the bottomfodliste_mm0–200 mm · step size 50 mmThe wall is carried down below the bottom. 0 = the wall's bottom edge is flush with the underside of the bottom at the drain.
The nozzle is locatedstuds_montageSvejst PÅ bundens underside (hul = studsens lysning) · Stukket IGENNEM bunden (hul = studsens ydermål)Svejst PÅ bundens underside (hul = studsens lysning)—

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Dairy vat 500 L — fall towards one corner

1,600 × 900, depth 420 → 320/370 mm. Fall 3.58° lengthwise and 3.18° crosswise — both above the 3° hygiene requires

Also known as: mejerikar · ostekar · mælkekar · procesbeholder · åbent kar

Scalding vat for a slaughterhouse

2,400 × 1,100 × 600 mm in 2.5 mm 1.4404. The bottom is 2,404.7 × 1,101.6 mm developed — only 4.7 mm more than the clear dimension

Also known as: shoulder bath · slagtekar · blødlægningskar · afsvedningskar · cooking pot

Drip tray under machine

900 × 600 × 90/55 mm — one-way fall, 39 L. Technical tank, not a food zone: 2.23° fall is below the hygiene requirement

Also known as: drypbakke · dryppebakke · opsamlingsbakke · spill tray · lækagebakke

Floor tray with drain — two-part bottom

2,000 × 1,200, four free corner depths 260/130/190/90 mm. The twist c = −30 mm is resolved with a diagonal seam, so both halves are EXACTLY flat

Also known as: gulvkar · procesgulv · opsamlingskar · gulvrende · spulekar

Rinsing sink for a commercial kitchen

1,000 × 600 × 300 mm, 1.5 mm 1.4301. Fall 3.43°/3.34° — just above the requirement, and that's deliberate

Also known as: skyllekar · opvaskekar · vaskekar · køkkenkar · grovvask

Feed trough for stables (hot-dip galvanised)

2,000 × 500 × 200/150 mm in DX51D, overlapped and riveted corners. NOT a food-contact surface

Also known as: foderkar · vandkar · drikkekar · staldkar · crib

Tank with TWISTED bottom — fall towards one corner

1,400 × 900, corner depths 220/140/165/120 mm. Twist c = −35 mm in ONE sheet: the model deviation is 0.194 mm at 45 facets

Also known as: snoet bund · vredet bund · hyperbolsk bund · kar med dobbeltfald · vridningsbund

Soaking tank for a bakery

1,200 × 700 × 350 mm, 248 L. The mean depth of 295 mm is the average of the four corner depths — not the depth at the drain

Also known as: blødlægningskar · dejkar · iblødsætningskar · vaskekar · bagerikar

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • The vessel is NOT sized for the liquid pressure. A 600 mm deep wall carries 6 kPa at the bottom, and a 2,400 mm long wall in 2.5 mm sheet will bulge out without stiffening. Open vessels are not covered by EN 13445 (pressure vessels) — load capacity and stiffening must be calculated separately.
  • The hygiene checks follow EHEDG's principles (fall towards one low point, no crevices, dead legs ≤ 2 · d_i, R_int ≥ 3 mm) as they are reproduced in the plan's §4.4. They do NOT replace an approval under Regulation (EC) 1935/2004 and (EC) 2023/2006 or a HACCP assessment of the finished installation.
  • The drain's capacity, trap and connection are not sized. The drainage installation falls under DS 432 and EN 12056 and must be designed by whoever is responsible for the drainage system.
  • Legs, base frame, hangers, anchoring and any lifting points are not included. The base strip is part of the wall blank and does not carry load on its own.
  • Thermal expansion has not been allowed for. A scalding tank going from 20 to 85°C expands 1.3 mm per metre in stainless steel (α ≈ 16.5 · 10⁻⁶ /K), and the suspension must be able to take that.
  • Welding distortion is not compensated for. A fillet weld all the way round in 1.5 mm sheet will pull the bottom up towards the walls; the vessel must be clamped or tack-welded at intervals before the continuous seam is laid.
  • The surface requirement (Ra ≤ 0.8 µm in the product zone, all seams ground and passivated) is a finishing specification, not geometry, and cannot be read from the pattern.

Onward from here