Part-cylindrical jacket
Half shell, quarter shell or full sheet-metal jacket around pipe and insulation. The development is exact: R_n·θ plus BAI overlap.
How true is the flat pattern?
The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.
Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
27 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Core — outside Ø of what the cladding goes roundkerne_diameter | 50–2.000 mm · step size 0,1 | 114,3 mm | The bare pipe, shaft or duct. The insulation is added on top of this further down — the tool calculates the shell's own diameter. |
| Insulation thickness, radialiso_tykkelse | 0–300 mm · step size 5 | 50 mm | All layers added together. 0 = the shell sits directly on the core. |
| Insulation type (determines the safety allowance)iso_type | Ingen isolering (kappen sidder på kernen) (+0 mm) · Lamella mat (+5 mm) · Pipe section (+10 mm) · Wire mesh mat (+10 mm) · Polyurethan (formstøbt) (+0 mm) | Pipe section (+10 mm) | The allowance is applied to the DIAMETER, not the radius. The figures are from the trade agreement's ‘Standard for measuring and sheet-metal fabrication’. |
| The cladding sits on a bendpaa_boejning | on / off | off | BAI adds 5 mm extra to the diameter in a bend. |
| Sector — how much of the circumference the shell coversudsnit | 30–360 ° · step size 5 | 180 ° | 180° = half section · 90° = quarter section · 360° = full shell with longitudinal seam. |
| Shells per ringantal_skaller | 1–8 stk · step size 1 | 2 stk | Two half shells close one circumference. Shells × sector should give 360°. |
| Shell length along the axislaengde | 50–3.000 mm · step size 10 | 1.000 mm | The length the cladding must cover. The tool splits into courses itself if the sheet is too short. |
| The two free long edgeslangkant | Overlæg på den ene kant · Flange på begge kanter · Opkant (sik) på begge kanter · Rå kanter | Overlæg på den ene kant | — |
| Overlap widthconditionaloverlaeg_kilde | Auto (BAI 20/35/50 mm) · Fixed dimension | Auto (BAI 20/35/50 mm) | — |
| Overlap, fixed dimensionconditionaloverlaeg_fast | 0–100 mm · step size 5 | 35 mm | — |
| Flange width (outside dimension)conditionalflange_bredde | 0–60 mm · step size 1 | 25 mm | Measured from the outer plane of the shell outwards. 0 = no flange. |
| Flange bend angleconditionalflange_vinkel | 30–120 ° · step size 5 | 90 ° | 90° = the flange stands perpendicular to the shell. Below 90° it closes in towards the mating part. |
| How the shell is held togetherfastgoerelse | Spændebånd udenom · Popnitter i overlægget · Selvskærende skruer i overlægget · Klips / snaplås | Selvskærende skruer i overlægget | — |
| Bands/clips per courseconditionalbaand_antal | 0–10 stk · step size 1 | 2 stk | The tool calculates the spacing from the number. The requirement for band spacing is set out in the insulation specification — the tool does not invent it. |
| Rolled beads (stiffening grooves) per sectionsikke_antal | 0–6 stk · step size 1 | 0 stk | Rolled grooves round the shell. They stiffen a large shell — and eat axial length. |
| Rolled bead depthconditionalsikke_h | 2–12 mm · step size 0,5 | 4 mm | — |
| Rolled bead widthconditionalsikke_w | 5–40 mm · step size 1 | 16 mm | Δ = 8·h²/(3·w) per groove. The formula is a flat-arc approximation and applies when h ≤ w/2. |
| End discs at both endsendeskiver | on / off | off | Semicircular plates that close the ends of the shell — insulation end cap against flange or valve. |
| The longitudinal seam is positionedsoem_klokke | 0–12 kl. · step size 0,5 | 6 kl. | 0 = 12 o'clock (top). Outdoors, the seam must be at 4–8 o'clock so water runs off the lap. |
| The cladding is outdoorsudendoers | on / off | off | Turns on the water path guard: the strap must face downwards, and the upper section must lie outside the lower one. |
| Goods thicknesst | 0,4–1,5 mm · step size 0,05 | 0,7 mm | Sheet-metal cladding is 0.5–1.0 mm. Thicker sheet cannot be beaded cleanly on a hand beading machine. |
| Materiallegering | Aluminium Al99.5 (1050A) · Aluminium AlMg3 (5754) · Hot-dip galvanised steel DX51D+Z · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316L | Aluminium Al99.5 (1050A) | — |
Advanced fields
Hidden by default — they have a sensible default, and most parts do not need them.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Extra clearance on the diameterluft_ekstra | 0–30 mm · step size 1 | 0 mm | In addition to BAI's safety allowance. Use it when the insulation is uneven or needs to be able to adjust. |
| Upstand height (0 = workshop standard)conditionalsik_maal | 0–20 mm · step size 1 | 0 mm | 0 uses the context's hem dimension. The tool always shows what BAI's beading wheel would give. |
| Axial overlap between courses (0 = as BAI)skud_overlaeg | 0–150 mm · step size 5 | 0 mm | The telescopic joint between two sections. 0 uses BAI's circumference figure, because the trade agreement has no figure of its own for the axial joint. |
| Number of courses (0 = the tool calculates it)antal_skud | 0–12 stk · step size 1 | 0 stk | Lock the number when the sheet stock or the installation requires a specific division. |
| Bend radius for flange/upstand (0 = same as material thickness)bukkeradius | 0–6 mm · step size 0,1 | 0 mm | The press brake's internal radius — NOT the shell's forming radius. The machine's own bend table takes precedence over any formula. |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Half shell, DN 100 with 50 mm pipe section
Two half-shells around Ø114.3 + 2 × 50 mm + 10 mm pipe-section allowance = Ø224.3 internal
Also known as: halvskål · halvskal · rørkappe · pladekappe rør · half shell
Full sheet-metal cladding round pipe (360°)
One piece all the way round with a longitudinal seam — the template's «cut length = π·D + overlap»
Also known as: pladekappe · rørkappe · kappe om rør · jacketing · beklædning
Removable valve cover with flanges
Two half shells with 25 mm flanges at 90° — bolted together and can be removed again
Also known as: ventilkappe · aftagelig kappe · boks om ventil · servicekappe · flangekappe
Tank segment, quarter shell 90°
Four quarter shells round a Ø1600 tank — developed width per shell ≈ 1.3 m
Also known as: kvartskål · tankkappe · tanksegment · kappesegment · skal til tank
Shaft guard (protective cover over shaft)
200° guard in 1.0 mm galvanised — covers most of the shaft, open underneath
Also known as: akselskærm · screen · shielding · beskyttelseskappe · guard
Outdoor half shell with seam at 6 o'clock
The lap faces downwards, so the rainwater runs off it instead of in under it
Also known as: udendørs kappe · vejrskærm · regnkappe · udvendig isolering · friluftskappe
Large shell with stiffening grooves
Ø1200 half shell with 3 rolled beads of 4 × 16 mm = 8.0 mm extra length in the height
Also known as: stivriller · sikker · afstivet kappe · storkappe · rullesikke
District heating bend, PUR with bend allowance
Polyurethane gives 0 mm safety allowance, but the bend gives 5 mm
Also known as: district heating · FJV · PUR-kappe · bøjningskappe · præisoleret
Stainless cladding with end discs
1.4404 in 0.8 mm with closed ends — marine and chloride-bearing environment
Also known as: rustfri kappe · 316 kappe · syrefast · hygiejnekappe · fødevarekappe
Strapped cover over channel
Half shell held by 3 strap bands per section — no holes in the sheet
Also known as: spændebånd · båndet kappe · afdækning · kanalkappe · banding
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- The tool calculates GEOMETRY. The shell's function as a weather screen — sealing strip, mastic in the overlap, drainage and penetrations — is NOT covered; it is given in the insulation specification and in BAI's ‘Standard for measuring and sheet-metal fabrication’.
- Thermal expansion and the need for expansion joints in long shell runs are NOT covered. The expansion spacing is given in the job specification — the tool does not invent it.
- Contact corrosion between shell, supports and pipe (aluminium against stainless steel, copper upstream of zinc) is NOT assessed. The choice of materials must be checked by whoever is designing the installation.
- A shell is NOT a pressure-bearing part. If the workpiece must hold pressure, PED and EN 13445 apply, and this figure cannot be used for that.
- Fire insulation, fire dampers (EN 15650) and penetrations through fire-separating building elements are certified systems and are NOT covered.
- The fixing has not been sized. The tool sets the hole pattern with a pitch ≤ 8·d and at least 7 per metre; the load capacity for rivet, screw, band and clip is with the supplier.
- In a food and drinking-water zone, an overlap and a rivet hole are CREVICES. Choose a welded design — the figure's overlap model does not apply there.
- The insulation's thickness, λ-value and layer build-up are NOT covered. Use the trade's insulation-thickness calculator for that, and enter the result here.
Onward from here
- Template: Sheet-metal jacket Insulation's own template for the same part — with jacket diameter, overlap and area consumption.
- Sheet-metal jacket Isolering · skabelon
- Material consumption Insulation
- Cylinder – sheet length for the body Metal worker
- Clinch nail – spacing and edge distance Metal worker
- Developed length in bending Metal fabricator
- Sheet development with K-factor Technical designer
- The box unfolder A whole box unfolded with dimensions on every side — the same bending maths.
- 3D-workshop All the platform's 3D figures, including those without a flat pattern.
- The whole library Every figure, grouped and searchable by the words you know them under.