Roof collar around a round pipe
Hullet i tagfladen er en ELLIPSE, ikke en cirkel — og manchettens underkant er en ren cosinus.
How true is the flat pattern?
The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.
Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
28 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Rørets udvendige Øroer_d | 50–800 mm · step size 1 | 110 mm | Målet UDEN PÅ røret — det er den flade manchetten skal kunne skydes ned over. På et isoleret stålaftræk er det kappens Ø, ikke røggasrørets. |
| Taghældning αtaghaeldning | 0–60 ° · step size 0,5 | 30 ° | Vinklen fra vandret. 45° er 1:1, 26,6° er 1:2, 18,4° er 1:3. Hældningen ER ellipsens excentricitet — jo stejlere tag, jo længere bliver hullet i faldretningen. |
| Goods thicknesst | 0,4–3 mm · step size 0,05 | 0,7 mm | Tagblik ligger på 0,6–0,8 mm. Tykkere gods bruges kun hvor kraven skal kunne trædes på. |
| Blikmaterialeblik | Titanzink (tagzink) · Kobber Cu-DHP · Aluminium AlMg3 (5754) · Varmforzinket stålplade DX51D+Z · Rustfrit 1.4404 / AISI 316L | Titanzink (tagzink) | — |
| Materiale opstrøms på tagetopstroems | Ingenting ovenfor · Copper · Bly · Titanzink · Aluminum · Stainless steel · Ubehandlet stål · Tagpap / bitumen | Ingenting ovenfor | Det der ligger OVENFOR kraven på taget. Kobber eller bly opstrøms for zink eller aluminium tærer blikket igennem — alt vandet ovenfra løber hen over kraven. |
| Kravehøjde over tagfladen (opstrøms)kravehoejde | 50–400 mm · step size 5 | 150 mm | Målt på den side der vender mod RYGNINGEN — dér vandet står. Nedstrøms bliver manchetten automatisk D_n·tan α højere, fordi overkanten er vandret. |
| Manchettens møde med kravepladenmontage | Manchetten ned gennem hullet · Manchetten står på kravepladen | Manchetten ned gennem hullet | Valget ændrer hullets bredde med 2·t + 2·loddespalte — det er ikke en teknikalitet. |
| Manchettens lodrette sømsoemtype | Loddet overlæg · Falset søm | Loddet overlæg | Loddet overlæg lægges på ÉN part. En falset søm bærer materiale på BEGGE parter — 3 lag à W. |
| Kravepladens ydermålpladeform | Regnet af overlappene · Faste ydermål (tastes) | Regnet af overlappene | — |
| Overlap opad (ind under tagdækningen)conditionaloverlap_op | 50–500 mm · step size 10 | 250 mm | Fra hullets kant og op mod rygningen. Svarer til en lodret vandsøjle på overlap·sin α. Mindstemålet står i tagdækningens egen læggeanvisning — værktøjet opfinder det ikke. |
| Overlap nedad (oven på tagdækningen)overlap_ned | 50–500 mm · step size 10 | 150 mm | Fra hullets kant og ned mod tagfoden. Bruges også når ydermålene tastes: hullet placeres altid så dette overlap holder, og resten bliver overlappet opad. |
| Overlap i sidenconditionaloverlap_side | 50–500 mm · step size 10 | 150 mm | — |
| Kravepladens bredde (på tværs af faldet)conditionalplade_b | 150–3.000 mm · step size 10 | 600 mm | — |
| Kravepladens højde (langs faldet)conditionalplade_h | 150–3.000 mm · step size 10 | 800 mm | — |
| Hjørneradius på kravepladenhjoerneradius | 0–200 mm · step size 5 | 25 mm | 0 = skarpe hjørner. Runde hjørner river ikke i undertaget og river ikke i hænderne. |
| Opkant hele vejen rundt om kravepladenopkant | on / off | off | — |
| Opkantens højdeconditionalopkant_h | 5–60 mm · step size 1 | 15 mm | Udvendigt mål. På den nederste kant skal opkanten klippes væk eller bukkes NEDAD som vandnæse. |
| Vandbræt (stormkrave) øverstvandbraet | on / off | on | — |
| Vandbrættets udhæng over manchettenconditionalvb_udhaeng | 5–100 mm · step size 5 | 25 mm | Hvor langt dryppekanten rækker ud over manchettens yderside, så vandet ikke løber ned ad sømmen. |
| Vandbrættets faldconditionalvb_fald | 5–120 mm · step size 5 | 40 mm | Lodret højde mellem klemkanten og dryppekanten. Uden fald står vandet på brættet. |
Advanced fields
Hidden by default — they have a sensible default, and most parts do not need them.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Luft mellem rør og manchetluft | 0–30 mm · step size 0,5 | 3 mm | Radial luft hele vejen rundt. Røret skal kunne bevæge sig i kraven; et varmt aftræksrør udvider sig, og en gennemføring der binder river i inddækningen. |
| Loddespalte i hulletconditionalloddespalte | 0–3 mm · step size 0,25 | 0,5 mm | Luften mellem manchettens yderside og hullets kant, så loddet kan trækkes igennem. |
| Manchettens nedstik under kravepladenconditionalnedstik | 0–60 mm · step size 5 | 10 mm | Hvor langt manchetten stikker ned under pladen. Lægges til blankettens længde, ikke til kravehøjden. |
| Loddeoverlæggets breddeconditionaloverlaeg_b | 5–60 mm · step size 1 | 20 mm | — |
| Falsbredde Wconditionalfals_w | 4–25 mm · step size 1 | 8 mm | Sømmen indeholder 3 lag à W; netto på omkredsen bliver 2·W. |
| Sømmens plads i forhold til faldetsoem_placering | Nedstrøms (modsat rygningen) · På tværs (i siden) · Opstrøms (mod rygningen) | Nedstrøms (modsat rygningen) | Sømmen er manchettens svageste sted. Læg den modsat den side vandet står på. |
| Vandbrættets overlap ned over manchettenconditionalvb_overlaeg | 10–150 mm · step size 5 | 40 mm | — |
| Klemluft mellem rør og vandbrætconditionalvb_klemluft | 0–10 mm · step size 0,5 | 1 mm | Vandbrættet klemmer om SELVE røret — ikke om manchetten. Derfor er luften her mindre. |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Faldstammeudluftning Ø110 i 30° tegltag
Storaksen bliver 136,7 mm mod lilleaksens 118,4 — 18,3 mm der ikke må gættes
Also known as: tagkrave · rørgennemføring · faldstammeudluftning · exhaust hood · aftræk
Ventilationsrør Ø160 i 45° tag
Ved 45° er storaksen √2 = 41,4 % længere end lilleaksen, og udsvinget i manchetten er 168,7 mm
Also known as: ventilationsrør · aftrækshætte · taghætte · emhætteaftræk · kanalgennemføring
Isoleret stålskorsten Ø200 i 25° tag
20 mm luft hele vejen rundt: skorstenen skal kunne bevæge sig, og kraven må ikke bære på den
Also known as: stålskorsten · skorstensinddækning · smoke pipe · brændeovnsaftræk · elementskorsten
Kobberkrave Ø110 i 40° skifertag
Kobber over kobber: 0,7 mm Cu-DHP med loddet søm — og kobber må ALDRIG ligge opstrøms for zink
Also known as: kobberkrave · kobberinddækning · skifertag · kobberblik · rørkrave i kobber
Falset zinkmanchet Ø125 i 35° tag
Falsen bærer 8 mm på hver part — netto 16 mm på omkredsen, og den skal med i blanketten
Also known as: falset søm · zinkmanchet · falsekrave · stående fals · blikkenslagersøm
Gennemføring Ø160 i lavt tag (8°)
Ved 8° er storaksen kun 1 % længere end lilleaksen — men vandsøjlen i overlappet er også kun 70 mm
Also known as: lav taghældning · fladt tag · tagpaptag · lavthældende tag · membrantag
Procesaftræk Ø400 i 20° industritag
Ø400 ved 20° giver et hul på 413 × 439,5 mm — 26,5 mm forskel, og manchetten svinger 149,6 mm
Also known as: procesaftræk · industritag · stor gennemføring · kanalrør · aluminiumskrave
Fast kravepladestørrelse 600 × 900 mm
Ydermålene er tastet: hullet lægges så overlappet NEDAD holder 150 mm, resten bliver overlap opad
Also known as: fast pladestørrelse · standardkrave · seriefremstillet krave · pladeformat · målfast krave
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- Fastgørelse, vindlast og forankring er IKKE dækket. En tagkrave sidder i en vindudsat bygningsdel og skal fastholdes efter EN 1991-1-4 og tagdækningens egne anvisninger — figuren leverer geometrien, ikke befæstelsen.
- Mindste taghældning, laplængder og krav til undertag hører til TAGDÆKNINGENS egen læggeanvisning. Figuren regner overlappenes geometri og den lodrette vandsøjle overlap·sin α; mindstemålet opfinder den ikke.
- Aftræk og skorstene er ikke dækket sikkerhedsmæssigt. Røggastemperatur, afstand til brændbart materiale, tætning mod røggas og krav til selve skorstensrøret følger EN 1856-1/-2 og Bygningsreglementets afsnit om ildsteder og skorstene — en tagkrave er en inddækning, ikke en skorstensdel.
- Kontaktkorrosions-vagten er en GEOMETRISK/materialemæssig huskeregel efter EN 12502-2: kobber og bly opstrøms for zink og aluminium giver gennemtæring. Den erstatter ikke en korrosionsvurdering af den konkrete bygning, og bly er ikke i materialelisten fordi repoet ikke har data for det.
- Termisk bevægelse er ikke dimensioneret. Blikkets længdeudvidelse står som materialedata (EN 988 for titanzink, EN 1172 for kobber), men rørets egen bevægelse afhænger af rørets materiale og driftstemperatur og skal komme fra rørleverandøren.
- Manchettens frie overkant leveres uden kanttillæg. En opkravning eller sik på en rund rand er krympning (ε = −b/r_n) og ikke bukning — kantpressens bukketillæg gælder ikke der.
- Undertag, dampspærre og tilslutningen mellem kravepladen og undertagets egen manchet er ikke i emnet. En tæt tagkrave i tagfladen hjælper ikke hvis undertaget under den er utæt.
- Lodning og falsning er ikke svejsedata. Flusmiddel, lodmetal, kapillarspalte og falsemaskinens indstilling hører til udførelsen; figuren leverer materialeforbruget og kantens hensigt.
Onward from here
- Rafter length & roof pitch Carpenter
- Batten spacing to roof tile Carpenter
- Cylinder – pladelængde til krop Metal worker
- Udfoldet længde ved bukning Metal fabricator
- Pladeudfoldning med K-faktor Technical designer
- The box unfolder A whole box unfolded with dimensions on every side — the same bending maths.
- 3D-workshop All the platform's 3D figures, including those without a flat pattern.
- The whole library Every figure, grouped and searchable by the words you know them under.