Valve box with rise
The school's U-box around a valve: half-round at the bottom, a rise up towards the spindle and end plates with or without a rise — lockformed or spring-seamed.
How true is the flat pattern?
The surface is faceted or triangulated, so the pattern is an approximation. The error is known and printed as a number on the drawing — it is not hidden.
Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
16 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Box diameter (inside)D | 60–1.500 mm · step size 1 | 250 mm | The flange's circumference divided by π, plus the insulation on both sides. |
| Spindle heightSP | 20–2.000 mm · step size 1 | 165 mm | From the centre of the valve up to the point on the spindle where the box is to end. Leave room for a couple of fingers under the handwheel. |
| LengthL | 50–3.000 mm · step size 1 | 400 mm | The outer points of the flanges plus bolt clearance; let the measurement go 20 mm in over the pipe's overlap seam at both ends. |
| Rise at the spindlestigning_top | 0–300 mm · step size 1 | 20 mm | The middle of the top above the corners so the water runs off. 0 = flat top. |
| End plate risebund_stigning | Rise in mm · Rise in degrees · Flat end plate | Rise in mm | — |
| Rise (mm)conditionalh_mm | 1–500 mm · step size 1 | 45 mm | How far the hole lies outside the end of the shell. |
| Rise (degrees)conditionalh_grader | 5–60 ° · step size 1 | 25 ° | Measured on the round part of the end plate. “25 to 30 degree rise” if the company has no figure. |
| Hole in the end plate (pipe Ø with insulation)hul_d | 10–1.400 mm · step size 1 | 120 mm | The hole sits at the centre of the large circle. |
| Drawn collar in the holekrave | 0–30 mm · step size 1 | 0 mm | 0 = plain hole. With a collar the hole is cut smaller so it ends up at the pipe's Ø. |
| End plate to shellendekant | Lockformed — Pittsburgh seam · Spring-seamed — seam made with a spring wheel | Lockformed — Pittsburgh seam | — |
| Pittsburgh pocket allowance per endconditionalpittsburgh_mm | 10–40 mm · step size 0,5 | 25 mm | The source says “about 22 - 25 mm”. Use your own test bend if it gives a different figure. |
| Seam material per endconditionalspraengt_sik_mm | 0–30 mm · step size 0,5 | 0 mm | Found by trial — the source gives no figure. 0 = nothing added. |
| Overlap in the seamsoverlaeg_b | 0–60 mm · step size 1 | 20 mm | The compendium draws 20 mm. 0 = the workshop rule. |
| The seams are joined withfastgoerelse | Screws (the box can be removed) · Pop rivets (permanent) | Screws (the box can be removed) | — |
| Goods thicknesst | 0,4–1,5 mm · step size 0,05 | 0,7 mm | Sheet jackets are 0.5–1.0 mm. |
| Materiallegering | Aluminium Al99.5 (1050A) · Aluminium AlMg3 (5754) · Hot-dip galvanised steel DX51D+Z · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316L | Aluminium Al99.5 (1050A) | — |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Valve box Ø250, spindle height 165, with rise
Offshore compendium pp. 6–7: Ø250, length 400, spindle height 165, 20 mm at the top and 45 mm in the end plate, hole Ø120
Also known as: ventilkasse 250 · ventilkasse med stigning
The Norsok trial: Ø220, spindle height 130, rise at spindle 20
Norsok trial: Ø220, spindle height 130, length 300, rise at spindle 20 mm, hole Ø110 with 10 mm flange = Ø130
Also known as: Norsok ventilkasse · ventilkasse offshore
Spring-seamed valve box without rise (indoors)
Under cover: flat top, flat end plate, spring-seamed (Offshore compendium p. 6)
Also known as: sprængt ventilkasse · U-kasse
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- The dimensions are the box's own inside dimensions. The insulation must be added to the diameter and length before they are entered.
- The spindle hole and the drain holes are not drawn: the sources do not give their dimensions. Mark out the spindle hole on the ridge, half in each half.
- The sources do not show how the bottom seam is closed when the box has to be removable. The compendium p. 6 shows toggle latches 40 mm from the edge on the ridge.
- The Pittsburgh allowance (22–25 mm) and the material taken by the spring-wheel seam depend on the machine. Adjust them after a test bend.
Onward from here
- Sheet-metal jacket Isolering · skabelon
- Material consumption Insulation
- The box unfolder A whole box unfolded with dimensions on every side — the same bending maths.
- 3D-workshop All the platform's 3D figures, including those without a flat pattern.
- The whole library Every figure, grouped and searchable by the words you know them under.