Skip to content

Elephant-foot tee (saddle tee)

A tee with a thickening towards the main pipe: an ordinary tee with a triangle that pushes one half out at a slant.

Approximate flat patternInside dimensions17 dimensions4 presets
Teknisk isolatoer …
Insulation
tee i elefantfod · elefantfod …
tee i elefantfod · elefantfod · elefantfod-tee · elefant tee · sadeltee · sadel tee · sadel-T · sadel T · T på bøjning · tee med halv bøjning · tee med fortykning · skrå halvcylinder

How true is the flat pattern?

The surface is faceted or triangulated, so the pattern is an approximation. The error is known and printed as a number on the drawing — it is not hidden.

Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

17 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
The formformSlanted to one side · Slanted to both sidesSlanted to one side—
Dimensions entered asmaal_fraThe insulated triangle · Pipe + insulationThe insulated triangle—
Main pipe diameter (inside dimension of the cladding)conditionalD_hoved40–1.000 mm · step size 1120 mmThe outside dimension of the insulation on the main pipe.
Tee diameter (inside dimension of the cladding)conditionalD40–1.000 mm · step size 1120 mmAt most the same diameter as the main pipe.
C1 — horizontal side of the triangleconditionalc5–1.000 mm · step size 176 mmMeasured on the insulated geometry, horizontally at the main pipe's centre line.
Y — from the centre of the main pipe to the tee's openingconditionalY20–2.000 mm · step size 1116 mmThe short length KL plus the radius of the main pipe (the school: 56 + 60 = 116).
Main pipe outside Ø (bare)conditionalroer_hoved10–800 mm · step size 0,160 mm—
Tee outside Ø (bare)conditionalroer_gren10–800 mm · step size 0,160 mm—
C1 on the bare pipe (per side)conditionalc_roer5–1.000 mm · step size 160 mmHorizontally from the tee's centre line, where the slanted side touches the main pipe's surface.
Centre length C3conditionalC320–2.000 mm · step size 1100 mmFrom the centre of the main pipe up to the tee's opening, on the bare pipe.
Insulation thicknessconditionaliso10–200 mm · step size 530 mm—
Bead at the tee's openingsik_lilleOver-bead (3 mm) · Under-bead (5 mm) · No beadOver-bead (3 mm)—
Flange collar against the main pipebertel0–20 mm · step size 110 mmThe school adds 10 mm for the flange collar.
Draw the hole in the main pipetegn_hulon / offonThe hole in the main pipe's cladding as an extra part: the foot of the tee laid out on the cladding, 1:1.
Goods thicknesst0,4–1,5 mm · step size 0,050,7 mmSheet jackets are 0.5–1.0 mm.
MateriallegeringAluminium Al99.5 (1050A) · Aluminium AlMg3 (5754) · Hot-dip galvanised steel DX51D+Z · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316LAluminium Al99.5 (1050A)—

Advanced fields

1

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Overlap on the longitudinal seamoverlaeg10–50 mm · step size 120 mmThe school marks a 10 mm edge on both sides = 20 mm overlap.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Elephant-foot tee Ø120, C1 76, Y 116

Film text «Tee i elefantfod»: Ø120 on Ø120, KL 56 + radius 60 = Y 116, over-bead at the opening

Also known as: tee i elefantfod 120 · sadeltee 120

Saddle tee Ø120, C1 98, Y 112

Video «Lektion 10 plade trin 3»: the insulated triangle 112 × 98, the combined version

Also known as: sadeltee video

Saddle tee Ø60 + 30 mm insulation, C1 60, C3 100

Video «Lektion 10 plade trin 3»: the triangle recalculated from the bare pipe

Also known as: sadeltee rør og isolering

Saddle tee slanted to both sides Ø120, C2 196, Y 112

Video «Lektion 10 plade trin 3»: the triangle 196 at the base, 98 to each side

Also known as: sadeltee begge sider

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • C1 and Y must be measured on the INSULATED geometry. The insulation lifts the kink more than the insulation thickness because the slanted side is inclined (video «Lektion 10 plade trin 3», AMU Syd). Use «Pipe + insulation» if you only know the bare pipe.
  • The slanted half is an oblique half-cylinder with a circular section at the tee's opening, as the school draws it. A welded half elbow under the insulation is not an oblique cylinder — the cladding follows the insulation, not the pipe.
  • The hole in the main pipe's cladding is drawn as a template: the foot of the tee laid out on the cladding. The sources do not develop it, so it is pure geometry without allowances. The tee is at most as large as the main pipe.

Onward from here