Skip to content

Roof collar around a round pipe

The hole in the roof surface is an ELLIPSE, not a circle — and the lower edge of the collar is a pure cosine.

Exact flat patternOutside dimensions28 dimensions8 presets
Vvs energi · Toemrer …
Plumbing · Carpenter · Bricklayer
tagkrave · rørgennemføring …
tagkrave · rørgennemføring · rørinddækning · manchet · stormkrave · vandbræt · aftræksinddækning · skorstensinddækning om rundt rør · taghætte · faldstammeudluftning · gennemføring i skråt tag

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

28 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Pipe outside Øroer_d50–800 mm · step size 1110 mmThe dimension OUTSIDE the pipe — it is the flat surface the sleeve must be able to slide down over. On an insulated steel flue it is the shell's Ø, not the flue-gas pipe's.
Roof pitch αtaghaeldning0–60 ° · step size 0,530 °The angle from horizontal. 45° is 1:1, 26.6° is 1:2, 18.4° is 1:3. The pitch IS the ellipse's eccentricity — the steeper the roof, the longer the hole becomes in the fall direction.
Goods thicknesst0,4–3 mm · step size 0,050,7 mmRoof sheet metal is 0.6–0.8 mm. Thicker gauge is only used where the collar must be walkable.
Sheet materialblikTitanium zinc (roofing zinc) · Copper Cu-DHP · Aluminium AlMg3 (5754) · Hot-dip galvanised steel sheet DX51D+Z · Stainless 1.4404 / AISI 316LTitanium zinc (roofing zinc)—
Material upstream on the roofopstroemsIngenting ovenfor · Copper · Bly · Titanium zinc · Aluminum · Stainless steel · Ubehandlet stål · Tagpap / bitumenIngenting ovenforWhat lies ABOVE the collar on the roof. Copper or lead upstream of zinc or aluminium will corrode the sheet right through — all the water from above runs across the collar.
Collar height above the roof surface (upstream)kravehoejde50–400 mm · step size 5150 mmMeasured on the side facing the RIDGE — where the water stands. Downstream the collar automatically becomes D_n·tan α higher, because the top edge is horizontal.
Where the sleeve meets the collar platemontageManchetten ned gennem hullet · Manchetten står på kravepladenManchetten ned gennem hulletThe choice changes the hole width by 2·t + 2·solder gap — it is not a technicality.
The sleeve's vertical seamsoemtypeSoldered overlap · Lock seamSoldered overlapA soldered overlap is placed on ONE part. A folded seam carries material on BOTH parts — 3 layers of W each.
Outside dimensions of the collar platepladeformRegnet af overlappene · Faste ydermål (tastes)Regnet af overlappene—
Overlap upwards (in under the roof covering)conditionaloverlap_op50–500 mm · step size 10250 mmFrom the edge of the hole up towards the ridge. Corresponds to a vertical water column of overlap·sin α. The minimum dimension is given in the roof covering's own laying instructions — the tool does not invent it.
Overlap downwards (on top of the roof covering)overlap_ned50–500 mm · step size 10150 mmFrom the edge of the hole down towards the eaves. Also used when the outer dimensions are entered: the hole is always placed so this overlap is maintained, and the rest becomes the overlap upwards.
Side overlapconditionaloverlap_side50–500 mm · step size 10150 mm—
Collar plate width (across the fall)conditionalplade_b150–3.000 mm · step size 10600 mm—
Collar plate height (along the fall)conditionalplade_h150–3.000 mm · step size 10800 mm—
Corner radius on the collar platehjoerneradius0–200 mm · step size 525 mm0 = sharp corners. Rounded corners don't tear the substrate and don't tear your hands.
Upstand all the way round the collar plateopkanton / offoff—
Upstand heightconditionalopkant_h5–60 mm · step size 115 mmOutside dimension. On the bottom edge the upstand must be cut away or bent DOWNWARDS as a drip edge.
Weather collar (storm collar) at the topvandbraeton / offon—
Weather collar overhang over the sleeveconditionalvb_udhaeng5–100 mm · step size 525 mmHow far the drip edge projects beyond the outside of the collar, so the water does not run down the seam.
Weather collar fallconditionalvb_fald5–120 mm · step size 540 mmVertical height between the clamping edge and the drip edge. Without a fall the water stands on the board.

Advanced fields

8

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Clearance between pipe and sleeveluft0–30 mm · step size 0,53 mmRadial clearance all the way round. The pipe must be able to move within the collar; a hot flue pipe expands, and a penetration that binds will tear at the flashing.
Solder gap in the holeconditionalloddespalte0–3 mm · step size 0,250,5 mmThe clearance between the outside of the sleeve and the edge of the hole, so the solder can be drawn through.
Sleeve insertion below the collar plateconditionalnedstik0–60 mm · step size 510 mmHow far the collar projects below the sheet. Added to the blank length, not to the collar height.
Solder overlap widthconditionaloverlaeg_b5–60 mm · step size 120 mm—
Seam width Wconditionalfals_w4–25 mm · step size 18 mmThe seam contains 3 layers of W each; net on the circumference becomes 2·W.
Seam position relative to the fallsoem_placeringNedstrøms (modsat rygningen) · På tværs (i siden) · Opstrøms (mod rygningen)Nedstrøms (modsat rygningen)The seam is the weakest point of the collar. Place it opposite the side where the water stands.
Weather collar overlap down over the sleeveconditionalvb_overlaeg10–150 mm · step size 540 mm—
Clamping clearance between pipe and weatherboardconditionalvb_klemluft0–10 mm · step size 0,51 mmThe weather collar clamps around the pipe ITSELF — not around the sleeve. That is why the clearance is smaller here.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Soil stack vent Ø110 in 30° tiled roof

The major axis becomes 136.7 mm versus the minor axis's 118.4 — 18.3 mm that must not be guessed

Also known as: tagkrave · rørgennemføring · faldstammeudluftning · exhaust hood · aftræk

Ventilation pipe Ø160 in 45° roof

At 45° the major axis is √2 = 41.4 % longer than the minor axis, and the deviation in the sleeve is 168.7 mm

Also known as: ventilationsrør · aftrækshætte · taghætte · emhætteaftræk · kanalgennemføring

Insulated steel chimney Ø200 in 25° roof

20 mm clearance all the way round: the chimney must be able to move, and the collar must not bear on it

Also known as: stålskorsten · skorstensinddækning · smoke pipe · brændeovnsaftræk · elementskorsten

Copper collar Ø110 in 40° slate roof

Copper over copper: 0.7 mm Cu-DHP with soldered seam — and copper must NEVER lie upstream of zinc

Also known as: kobberkrave · kobberinddækning · skifertag · kobberblik · rørkrave i kobber

Seamed zinc sleeve Ø125 in 35° roof

The seam takes 8 mm on each part — net 16 mm on the circumference, and it must be included in the blank

Also known as: falset søm · zinkmanchet · falsekrave · stående fals · blikkenslagersøm

Penetration Ø160 in low-pitched roof (8°)

At 8° the major axis is only 1 % longer than the minor axis — but the water column in the overlap is also only 70 mm

Also known as: lav taghældning · flat roof · tagpaptag · lavthældende tag · membrantag

Process extract Ø400 in a 20° industrial roof

Ø400 at 20° gives a hole of 413 × 439.5 mm — 26.5 mm difference, and the sleeve deviates 149.6 mm

Also known as: procesaftræk · industritag · stor gennemføring · kanalrør · aluminiumskrave

Fixed collar plate size 600 × 900 mm

The outside dimensions have been entered: the hole is placed so the overlap DOWNWARDS keeps 150 mm, the rest becomes overlap upwards

Also known as: fast pladestørrelse · standardkrave · seriefremstillet krave · pladeformat · målfast krave

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • Fixing, wind load and anchoring are NOT covered. A roof collar sits in a wind-exposed building component and must be retained in accordance with EN 1991-1-4 and the roof covering's own instructions — the figure supplies the geometry, not the fastening.
  • Minimum roof pitch, lap lengths and requirements for the underlay belong to the ROOF COVERING'S own laying instructions. The figure calculates the overlaps' geometry and the vertical water column overlap·sin α; it does not invent the minimum dimension.
  • Flues and chimneys are not covered from a safety perspective. Flue-gas temperature, distance to combustible material, sealing against flue gas and requirements for the chimney pipe itself follow EN 1856-1/-2 and the Building Regulations' section on stoves and chimneys — a roof collar is a flashing, not a chimney component.
  • The contact-corrosion check is a GEOMETRIC/material-based rule of thumb in accordance with EN 12502-2: copper and lead upstream of zinc and aluminium cause corrosion right through. It does not replace a corrosion assessment of the specific building, and lead is not in the material list because the repo has no data for it.
  • Thermal movement is not sized. The sheet's linear expansion is given as material data (EN 988 for titanium zinc, EN 1172 for copper), but the pipe's own movement depends on the pipe's material and operating temperature and must come from the pipe supplier.
  • The sleeve's free top edge is supplied without an edge allowance. A flange or bead on a round rim is shrinking (ε = −b/r_n), not bending — the press brake's bend allowance does not apply there.
  • The underlay, vapour barrier and the connection between the collar plate and the underlay's own sleeve are not in the piece. A tight roof collar in the roof plane does not help if the underlay beneath it is not watertight.
  • Soldering and seaming are not welding data. Flux, solder metal, capillary gap and the seaming machine's setting belong to the execution; the figure supplies the material consumption and the intent of the edge.

Onward from here