Skip to content

Angled tee on a reducer (cylinder branch on a cone)

A round branch set at an angle on a reducer: the branch is developed by the parallel-line method against the cone, and the cone is triangulated.

Approximate flat patternInside dimensions22 dimensions1 presets
Teknisk isolatoer …
Insulation
skrå tee mod reduktion …
skrå tee mod reduktion · skrå T mod reduktion · skrå tee-stykke mod reduktion · tee på reduktion · T på reduktion · T på kegle · tee på kegle · cylindergren på kegle · cylinder-gren på kegle · gren på reduktion · rund tee på reduktionsstykke · T-stykke på reduktion

How true is the flat pattern?

The surface is faceted or triangulated, so the pattern is an approximation. The error is known and printed as a number on the drawing — it is not hidden.

Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

22 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Dimensions entered asmaal_fraCladding dimensions · Pipe + insulationCladding dimensions—
Reducer large Ø (inside dimension of the cladding)conditionalD_stor40–1.500 mm · step size 1230 mm—
Reducer small Ø (inside dimension of the cladding)conditionald_lille20–1.500 mm · step size 1130 mm—
Branch Ø (inside dimension of the cladding)conditionald_gren20–1.500 mm · step size 1100 mm—
Pipe outside Ø at the large end (bare)conditionalroer_stor10–1.200 mm · step size 0,1170 mm—
Pipe outside Ø at the small end (bare)conditionalroer_lille10–1.200 mm · step size 0,170 mm—
Branch pipe outside Ø (bare)conditionalroer_gren10–1.200 mm · step size 0,140 mm—
Insulation thicknessconditionaliso10–200 mm · step size 530 mm—
Reducer lengthH20–3.000 mm · step size 1300 mmAlong the axis from the small end to the large one.
Branch angle to the reducer axisvinkel15–165 ° · step size 0,545 °Between the branch axis and the reducer axis towards the large end. 90° is a straight tee.
The branch axis meets the reducer axisplacering0–3.000 mm · step size 130 mmThe height above the small end where the two axes meet.
Branch lengthgrenlaengde20–3.000 mm · step size 1320 mmAlong the branch axis from the reducer axis out to the branch end x.
Flange collar against the conebertel0–20 mm · step size 110 mmThe drawing says «Husk at lave tillæg til bærtel» (remember the allowance for the flange collar) without a dimension; 10 mm is the school's figure from the conical tee.
Draw the hole in the conetegn_hulon / offonThe hole in the cone's cladding as an extra part: the foot of the branch laid out on the cone, 1:1.
Branch seamsoem_grenAt 3 (as the drawing) · At 6 · At 12At 3 (as the drawing)If the cutting file cannot be made with the seam at 3, move it to 6 or 12 — there the curve always meets the seam at a right angle.
Bead at the branch end xsik_grenNo bead · Over-bead (3 mm) · Under-bead (5 mm)No bead—
Bead at the reducer's large endsik_storNo bead · Over-bead (3 mm) · Under-bead (5 mm)No bead—
Bead at the reducer's small endsik_lilleNo bead · Over-bead (3 mm) · Under-bead (5 mm)No bead—
Goods thicknesst0,4–1,5 mm · step size 0,050,7 mmSheet jackets are 0.5–1.0 mm.
MateriallegeringAluminium Al99.5 (1050A) · Aluminium AlMg3 (5754) · Hot-dip galvanised steel DX51D+Z · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316LAluminium Al99.5 (1050A)—

Advanced fields

2

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Overlap on the branch seam (0 = workshop rule)overlaeg_gren0–60 mm · step size 10 mm0 lets the workshop's overlap rule set the width by diameter.
Overlap on the cone seam (0 = workshop rule)overlaeg_kegle0–60 mm · step size 10 mm0 lets the workshop's overlap rule set the width by diameter.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Reducer Ø230 → Ø130, 300 long, branch Ø100 at 45°

Exercise booklet p. 24 «Skrå Tee-stykke mod reduktion»: D 230, D 130, 300 long, branch D 100 at 45°. The axis intersection (approx. 30) and the branch length (approx. 320) are read off the drawing — they are not dimensioned

Also known as: skrå tee 230 130 · tee på reduktion 45

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • The source is a single drawing without text: «Skrå Tee-stykke mod reduktion» in the exercise booklet (BAI/AMU Syd 2009) p. 24. Where the branch axis meets the reducer axis, and how long the branch is, are not on the drawing — enter them yourself.
  • The branch axis meets the reducer axis (no side offset), as on the drawing. An offset branch is not included.
  • The drawing does not develop the hole in the cone. The figure draws it as a template: the foot of the branch laid out on the cone's cladding — pure geometry without allowances.
  • The drawing does not show where the cone seam sits relative to the branch. The figure puts it on the side facing away from the branch.
  • The drawing only says «Husk at lave tillæg til bærtel» (remember the allowance for the flange collar) and shows no bead or overlap. The flange collar (10 mm) and the bead (3/5 mm) are the school's figures from other material; the overlap follows the workshop rule.

Onward from here