Skip to content

Valley and ridge

Valley, hip and ridge from one folded strip — at 45°/45° the opening angle is 120°, not 90°.

Exact flat patternOutside dimensions21 dimensions10 presets
Vvs energi · Tagdaekker · Toemrer …
Plumbing · Carpenter · Bricklayer
skotrende · skotrenderende …
skotrende · skotrenderende · kilrende · renderyg · valley · rygning · rygningskappe · tipping · kipkappe · burr · gratkappe · valm · valmgrat · tagvinkel · midterkam · vandbrems · tagblik

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

21 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
The cornervariantSkotrende — indadgående hjørne (kilrende) · Grat — udadgående hjørne på en valm · Rygning — kip mellem to modstående tagfladerSkotrende — indadgående hjørne (kilrende)—
Roof plane 1 — slope α₁alfa15–60 ° · step size 0,545 °The slope of one roof face, measured from horizontal. 45° is 1:1.
Roof plane 2 — slope α₂alfa25–60 ° · step size 0,545 °The two roof faces don't need the same pitch — the bend is then simply not symmetrical.
Base angle in plan ψconditionalgrundvinkel45–135 ° · step size 190 °The angle between the two roof planes' FALL DIRECTIONS, seen from above. 90° is the usual right-angled corner. At 180° it is a ridge — choose that variant instead.
Full wing width in the roof planevingebredde100–500 mm · step size 5250 mmMeasured IN THE ROOF PLANE, perpendicular to the line — from the keel (the valley fold) to the outermost edge, including the upstand. This is NOT the same as the measurement along the eaves.
Flat bottom/top (0 = pure wedge)bundbredde0–200 mm · step size 50 mmWith a flat bottom, the bend is split in two: θ₁ on the left side and θ₂ on the right. Without a bottom there is one bend.
Upstand heightconditionalopkant_h0–100 mm · step size 525 mmBent 90° on the wing and therefore stands perpendicular TO THE ROOF PLANE. It is taken from the wing's outermost dimension, so the coverage becomes wing width minus upstand.
Centre ridge in the bottomconditionalmidterkamon / offoffWater check that prevents water running across the gutter from one roof plane to the other.
Centre ridge heightconditionalkam_h5–40 mm · step size 115 mmThe flanks are at 45°, so the ridge uses 2 × the height of the bottom width.
Lengthlaengde500–6.000 mm · step size 504.000 mm—
The length is measuredlaengdemaadeVandret, målt på plantegningen · Skråt, målt langs selve linjenVandret, målt på plantegningen—
Section lengthsektionslaengde500–6.000 mm · step size 1002.000 mmThe length of one piece. Limited by the band's manageable length and by transport.
Overlap per jointoverlaeg0–400 mm · step size 10150 mmAt least 100 mm (the plan's §5). With a small fall it must be more.
Number of identical partsantal1–20 stk · step size 11 stk—
Roof flashingtagmaterialeTitanium zinc (roofing zinc) · Copper · Aluminium (AlMg3) · Hot-dip galvanised steel sheet · Stainless 1.4301Titanium zinc (roofing zinc)—
Goods thicknesst0,6–1 mm · step size 0,050,7 mm—
The two free edgeskantafslutningSkarp klippekant · Ombuk (hem, 180°) · Rullet sikOmbuk (hem, 180°)A hem removes the burr and stiffens the edge, so the wing doesn't ripple under the roof tiles.
Edge heightconditionalkant_h5–30 mm · step size 110 mm—
End piecesendestykkerIngen endestykker · Nederste ende (ved tagfoden) · Øverste ende (ved kippen) · Begge enderIngen endestykkerA sheet cut to the cross-section, soldered or riveted at the end.

Advanced fields

2

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Bend radius (0 = the material's minimum)bukkeradius0–10 mm · step size 0,10 mm—
K-factor (0 = auto)k_faktor0–0,5 · step size 0,0050The machine's own bend table beats any formula. 0 = the DIN 6935 suggestion.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Valley gutter, 45°/45° roof

The kink is 60.000° and the opening 120.000° — not 90°

Also known as: skotrende · kilrende · renderyg · valley · skotrenderende

Valley gutter under a tiled roof, 25°

The opening is 145.225°, and the line only falls 18.25°

Also known as: tegltag · skotrende tegl · vingetegl · kilrende tegl · lav taghældning

Valley gutter between 40° and 20° roof surfaces

Unequal slopes: the bend is divided unevenly — θ₁ ≠ θ₂, and the bottom is not symmetrical

Also known as: ulige tag · asymmetrisk skotrende · tilbygning · udestue · sadeltag mod pulttag

Valley gutter in an oblique corner (60° in plan)

The base angle is not 90°, and then none of the rules of thumb hold

Also known as: skævt hjørne · vinklet tilbygning · karnap · skæv skotrende · ikke retvinklet

Wide valley gutter with centre ridge

120 mm bottom with a 20 mm water check, so the water doesn't run across the gutter

Also known as: midterkam · vandbrems · vandnæse i rende · bred skotrende · kilrende med kam

Long valley gutter in copper, sections of 3 m each

6 m in plan becomes 7.35 m along the line at 45° — the plan figure is missing 18.35 % of the part

Also known as: kobberrende · lang skotrende · sektionsdelt · kobber skotrende · kobberblik

Ridge capping, 30°/30° roof

The bend is 60° = α₁ + α₂ — here the naive rule IS right

Also known as: rygning · tipping · rygningskappe · kipkappe · rygningsblik

Ridge capping over an asymmetric roof (45°/20°)

ρ = 65°, and the two flaps stand 45° and 20° from the horizontal top side

Also known as: asymmetrisk rygning · skæv kip · pulttagskappe · ulige tagflader · rygning ulige

Hip capping on hipped end, 45°

Same bend as the valley gutter at the same pitches — only the bend direction is reversed

Also known as: burr · gratkappe · valm · valmgrat · hjørnekappe

Valley gutter in hot-dip galvanised steel, industrial roof 10°

Low pitch: the line falls only 7.1°, so the overlap must go up to 250 mm

Also known as: industritag · trapezplade · stålskotrende · lav hældning · hal

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • The development is EXACT — a chain has no geometric approximation. The entire uncertainty lies in the K-factor, and that belongs to the material, not the geometry. Always make a trial bend on the batch that will be used.
  • DIN 6935 covers ONLY structural steel. For titanium zinc, copper, aluminium and stainless steel the K-factor is an extrapolation — the machine's own bend table takes precedence over any formula.
  • The requirement for at least 100 mm coverage on each side and at least 100 mm section overlap is the plan's §5 figure. The current instructions for that particular roof covering take precedence; look it up with the supplier — the tool does not invent it.
  • The gutter's CAPACITY has not been calculated. How much water a valley gutter can carry depends on the roof area, the rainfall intensity and the drainage downstream (DS 432 for drainage), and that is a different calculation from this one.
  • Fixing, wind load and snow load are NOT covered. A valley gutter in a low-pitched roof can become filled by snow melting from above, and both clips and substrate must be sized in accordance with EN 1991-1-3/-1-4.
  • Contact corrosion is not assessed: copper upstream of zinc or aluminium will eat right through the sheet. Execute the whole drainage system in the same metal, or check the sequence against EN 12502-2.
  • Expansion is not calculated here. Titanium zinc moves approx. 0.022 mm per metre per kelvin, and a long valley gutter must be able to work at the joints — so do not rivet through both layers.
  • The end piece is supplied as a plate cut to the cross-section's MEASURING LINE. The material thickness has not been deducted; cut the plate 1 mm smaller all the way round, so it can fit down into the profile.

Onward from here