Chimney flashing, 4-part
4-part chimney flashing in sheet metal: front apron, two sides and back gutter. The bends are 90−α, 90 and 90+α — only the sides' bend is independent of the roof pitch.
How true is the flat pattern?
The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.
Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
21 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Roof pitch αtaghaeldning | 5–60 ° · step size 0,5 | 45 ° | The roof plane's pitch. It governs EVERYTHING: the side piece's length is the depth/cos α, the front edge is bent 90 − α, the back piece 90 + α — and the side piece is bent 90° regardless. |
| Chimney width (across the fall)skorsten_bredde | 200–2.000 mm · step size 10 | 600 mm | OUTSIDE masonry dimension, not the opening dimension. Measure on the finished, rendered chimney. |
| Chimney depth (in the direction of fall)skorsten_dybde | 200–2.000 mm · step size 10 | 600 mm | HORIZONTAL dimension in plan — not measured along the roof. The tool converts to the roof plane itself with 1/cos α. |
| Upstand height above the roof surfaceopkant_h | 100–300 mm · step size 5 | 150 mm | Measured PERPENDICULAR to the roof plane — that is the height water and snow must clear. 150 mm is the tool's starting value and good workshop practice, not a standard figure here: the roof covering's own instructions take precedence. |
| Overlap out on to the roof surfaceoverlap_tag | 100–400 mm · step size 10 | 200 mm | The roof leg's width: how far the flashing extends over/under the roof covering. Also determines the back gutter's width, which is the chimney width + 2 × this dimension. |
| Extra roof leg on the back piecebagben_tillaeg | 0–800 mm · step size 10 | 150 mm | The back is the exposed side: the water from the whole roof plane above must pass around the chimney. The leg must therefore extend further up under the roof covering than at the front and sides. |
| Corner overlap between the partshjoerne_overlaeg | 50–300 mm · step size 10 | 100 mm | How much the parts overlap each other at the corners. The dimension is ALREADY included in the blanks' widths — overlap must not be added a second time. |
| Side piece finishudfoerelse | Glat — ét sidestykke pr. vange · Trindelt — stigtrin efter skiftegangen | Glat — ét sidestykke pr. vange | — |
| Course height (one course of brickwork)conditionaltrin_hoejde | 30–200 mm · step size 1 | 66 mm | Brick height + bed joint. Danish standard brick 54 + 12 = 66 mm (trade dimension, the same figure as the bricklaying trade's calculator ‘Course height’). Measure it on the chimney — a different brick format has a different coursing. |
| Overlap per stepconditionaltrin_overlaeg | 30–200 mm · step size 5 | 80 mm | How much each step covers the step below. The same measurement is used for the cover piece's overhang beyond one course. |
| Back gutter fall towards the sidesbagrende_fald | 0–100 ‰ · step size 1 | 25 ‰ | 0‰ means the water stands behind the chimney. The fall is created by wedging the gutter bottom up in the middle; the gutter is then supplied in two halves that each fall towards their own side. |
| Continuous weatherboard on the back piecevandbraet | on / off | on | Upturn on the upper edge of the roof leg that stops water driven up under the roof covering. |
| Weather collar heightconditionalvandbraet_h | 15–60 mm · step size 5 | 30 mm | — |
| The free edgesfri_kant | Enkelt ombuk (180°) · Opkant/sik (90°) · Skarp klippekant | Enkelt ombuk (180°) | Treatment of the sheet's free edges — it stiffens the edge and removes the shear burr. |
| Edge dimensionsconditionalfri_kant_h | 10–25 mm · step size 1 | 12 mm | — |
| Sheet materialmateriale | Titanium zinc (roofing zinc) · Copper · Aluminum · Stainless 1.4301 | Titanium zinc (roofing zinc) | Lead is not on the list: lead is worked and follows double-curved shapes, and therefore cannot be supplied as a flat cutting pattern. |
| Goods thicknesst | 0,5–1,5 mm · step size 0,05 | 0,7 mm | 0.7 mm is standard for titanium-zinc flashings. Check against the supplier's stock list. |
| Joint between the partssoemtype | Blødloddet overlæg · Falset (fals eller dobbeltfals) · Klemt overlæg (glidende) | Falset (fals eller dobbeltfals) | — |
Advanced fields
Hidden by default — they have a sensible default, and most parts do not need them.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Cover piece insertion into the bed jointconditionalfugeindstik | 15–40 mm · step size 1 | 25 mm | How deep the cover piece is inserted into the raked-out bed joint before it is repointed. |
| Working temperature (sheet and workshop)conditionalarbejdstemperatur | -10–40 °C · step size 1 | 15 °C | Titanium zinc must not be bent or seamed below approx. 10 °C — the material cracks in the outer fibre. |
| Bend radius (0 = the material's minimum)bukkeradius | 0–3 mm · step size 0,1 | 0 mm | The machine's own bend table takes precedence over any formula. 0 = the material's minimum radius × t. Above 3 mm on 0.5–1.5 mm building sheet, the bend zone eats into the free edge's own leg. |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Step flashing, tiled roof 45°
The side piece becomes 848.5 mm long, not 600 — and the rear edge is bent 135°
Also known as: trappeinddækning · stigtrin · skorstensinddækning tegl · trindækning · step flashing
Concrete roof tiles 25°, stepped
Flat tiled roof: the front edge is bent 65° and the back edge 115° — the upstand leg becomes 176.5 mm
Also known as: betontagsten · tagstensinddækning · skorstensinddækning beton · vingetegl · trappeblik
Copper flashing, slate roof 30°
Copper 0.6 mm, stepped to the brickwork courses — 66 mm per course, not to the slate dimensions
Also known as: kobberinddækning · skiferinddækning · kobberblik skorsten · skifertag · kobbertrappe
Smooth flashing, roofing felt 15°
Low pitch: high upstand, long back leg and 40 ‰ fall in the back gutter
Also known as: tagpapinddækning · skorstensinddækning tagpap · glat inddækning · papinddækning · klemskinne skorsten
Stainless flashing, industrial roof 10°
Stainless 0.8 mm, clamped joint — 300 mm upstand because the water is driven up a 10° surface
Also known as: rustfri inddækning · industriskorsten · trapezplade inddækning · stålskorsten inddækning · rustfrit blik
Aluminium, seamed — 30° roof
Aluminium cannot be soft-soldered; all seams are lock seams
Also known as: aluminiumsinddækning · alu-blik · aluminium skorsten · falset inddækning · alu-inddækning
Wide chimney (1,400 mm) with back gutter
1,800 mm gutter with 35 ‰ fall ⇒ 31.5 mm packing at the centre
Also known as: bagrende · skorstensrende · bred skorsten · rende bag skorsten · sadel bag skorsten
Steep tiled roof 55°
The rear edge is bent 145° — so close to a seam that the press brake can't close it in one stroke
Also known as: stejlt tag · mansard · skifertag stejlt · tårn skorsten · 55 grader tag
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- The development is EXACT — all four parts are flat surfaces connected by straight bend lines, and a chain has no geometric approximation. The entire uncertainty lies in the K-factor, and that belongs to the material, not the geometry. Always make a trial bend on the batch that will be used.
- The figure calculates a VERTICAL chimney with a rectangular base plan on ONE flat roof plane. Chimneys that break through the ridge or a valley gutter, raked chimneys, and chimneys on curved roof planes are not covered.
- Upstand heights, roof overlap and corner overlap are PARAMETERS with workshop starting values. They are not standard figures in this tool — the roof covering's and the chimney's own installation instructions take precedence.
- The chimney's height above the roof plane and above the ridge, the flue's function and the requirements for certified chimney pipes (EN 1856) lie OUTSIDE the scope of the figure. That is the chimney sweep's and the building regulations' domain.
- DIN 6935 covers ONLY structural steel. For titanium zinc, copper, aluminium and stainless steel the K-factor is an extrapolation — the machine's own bend table takes precedence over any formula.
- Contact corrosion has not been calculated through for the whole drainage system. Copper must NEVER be placed upstream of titanium zinc, aluminium or galvanised steel (EN 12502-2); the reverse order is harmless.
- Fixing, wind load and anchoring are NOT covered. A flashing on a free-standing chimney is a wind-exposed building component and must be sized in accordance with EN 1991-1-4 and the roof covering's instructions.
- The underlay, vapour barrier and the seal against the roof structure beneath the flashing are outside the scope of this figure. The flashing is the outermost, not the only, seal.
Onward from here
- Roof pitch: fall, percentage and ratio Tagdaekker
- Course height Bricklayer
- Chimney height above roof Chimney sweep
- Rafter length and roof surface area Traefagenes byggeuddannelse
- Developed length in bending Metal fabricator
- Sheet development with K-factor Technical designer
- The box unfolder A whole box unfolded with dimensions on every side — the same bending maths.
- 3D-workshop All the platform's 3D figures, including those without a flat pattern.
- The whole library Every figure, grouped and searchable by the words you know them under.