Skip to content

Channel and trough with fall

U, trapezoidal, half-round or V drawn out lengthways — with a fall in the base or the whole gutter, end caps, sections and litres.

Exact flat patternLitre-drivenInside dimensions20 dimensions9 presets
Smed · Metalsmed …
rende · trug · kar · foderrende …
rende · trug · kar · foderrende · staldrende · afløbsrende · gulvrende · spånrende · kornrende · kondensrende · lænserende · procesrende · v-rende · halvrund rende · iskar · crib · duct

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

20 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Cross-sectiontvaersnitU — lodrette sider · Trapez — skrå sider · Halvrund — cirkelbue · V — to skrå fladerU — lodrette sider—
Horizontal spandriverlaengde200–6.000 mm · step size 503.000 mmThe length the gutter must cover, measured horizontally. The gutter's own length becomes longer when there is a fall.
Inside widthdriverbredde50–1.500 mm · step size 10300 mmU and trapezoid: clear dimension of the bottom. Half-round: chord of the opening. V: clear dimension of the top edge.
Inside depthdriverdybde20–800 mm · step size 10200 mmMeasured vertically from the plane of the top edge to the inside of the bottom. With «the bottom falls» it is the SHALLOW end.
Side slope from verticalconditionalsidehaeldning0–60 ° · step size 115 °0° = vertical sides (U). The bend angle becomes 90° − the slope.
Fall in the longitudinal directionfald_promille0–100 ‰ · step size 110 ‰10 ‰ = 1 cm per metre. The minimum fall is given in the drainage standard or the manufacturer's instructions.
How the fall is providedconditionalfaldmodelHele renden hælder (konstant tværsnit) · Vandret overkant, bunden falderHele renden hælder (konstant tværsnit)—
The gutter carries watervandfoerendeon / offonTurn off for feed troughs, chip troughs and vats — they must not have a fall.
Treatment of the top edgeskanttypeSkarp klippekant · Opkant (bukket sik) · Ombuk (180° hem) · Flad fals · Udadgående flangeOpkant (bukket sik)Applies to both free top edges. A sharp cut edge is only acceptable where the edge is hidden.
Top edge heightconditionalkant_h3–80 mm · step size 112 mmOutside dimension. If it is smaller than the bend zone (OSSB), the flat leg disappears — and you are told so clearly.
EndsendebundeÅbne ender (renden fortsætter) · Endebund, svejst/loddet i tværsnittet · Endebund med flange hele vejen rundtEndebund, svejst/loddet i tværsnittet—
End head flange widthconditionalendeflange5–50 mm · step size 115 mmThe flange runs all the way round. On a semicircular cross-section it is SHRINKING, not bending.
Number of sections along the lengthantal_sektioner1–6 stk · step size 11 stkThe gutter is divided crosswise into sections of equal length. Increase the number when the gutter is longer than the machine.
Joint between sectionsconditionalsektionssamlingOverlæg, nittet · Overlæg, klemt (glidende) · Stående fals · Stumpsvejst (tæt, ingen spalte)Overlæg, klemt (glidende)Only butt welding is gap-free. In the food zone everything else is prohibited.
Overlap per section jointconditionalsektion_overlaeg0–200 mm · step size 540 mm—
Goods thicknesst0,5–6 mm · step size 0,11,5 mm—
AlloyinglegeringAs the context (the engine's material choice) · Stainless 1.4301 / AISI 304 · Stainless 1.4404 / AISI 316L (food/CIP) · Black steel S235JR (painted) · Hot-dip galvanised steel sheet DX51D+Z · Aluminium AlMg3 (5754)Stainless 1.4301 / AISI 304The designation goes into the parts list — a 1.4404 gutter must not be ordered on the 1.4301 line.
Number of identical guttersantal1–50 stk · step size 11 stk—

Advanced fields

2

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Bend radius (0 = the material's minimum)bukkeradius0–20 mm · step size 0,50 mm—
K-factor (0 = auto)k_faktor0–0,5 · step size 0,0050The machine's own bend table beats any formula. 0 = the DIN 6935 suggestion.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Feed trough / stable gutter (U 400 × 250)

Galvanised 2 mm, no fall, folded edge on both top edges — the feed must be able to be scraped out

Also known as: foderrende · staldrende · fodertrug · crib · foderkrybbe · trug

Drainage channel in a milking parlour (U 300 × 150, 10 ‰)

Stainless 1.5 mm with horizontal top edge and falling bottom — the floor must be level, not the gutter

Also known as: malkestald · afløbsrende · gyllerende · staldafløb · rendeafløb

Floor gutter in slaughter passage (trapezoid, 1.4404, 15 ‰)

Sloping sides 20°, butt-welded and crevice-free — a strapped joint cannot be CIP-cleaned

Also known as: slagtegang · gulvrende · blodrende · hygiejnerende · slagterirende · afløbsrende

Half-round process gutter, dairy (Ø300, 10 ‰)

Semicircle R = 150 mm in 1.4404 — the whole gutter hangs with a fall, so the cross-section is constant

Also known as: mejerirende · procesrende · vallerende · spildrende · halvrund rende

Chip trough under a machine table (V 500 × 250)

V cross-section so the chips fall to the bottom by themselves — the apex angle becomes 90.0°, not 60°

Also known as: spånrende · spånskuffe · spåntransportør · v-rende · spånbakke

Grain gutter / auger trough (V 300 × 200)

Galvanised 2 mm in two sections — the bottom is a line, so no grain is left behind

Also known as: kornrende · sneglerende · transportrende · kornsnegl · indløbsrende

Ice tray for fish and meat (U 600 × 400, 300 L)

1.25 m long tank in 1.4301 — 600 × 400 × 1,250 mm gives exactly 300.0 L

Also known as: iskar · isbeholder · fiskekar · kølekar · trug · kar

Scupper gutter on deck (U 200 × 80, 20 ‰)

Aluminium 3 mm with flange for bolting — the whole gutter slopes, so the deck stays flat

Also known as: lænserende · dæksrende · spygat · skanserende · vandrende

Condensate gutter under cooling coil (trapezoid 200/30°, 5 ‰)

Flat trapezoid in 1 mm stainless, bead on both top edges — 5 ‰ is enough when the gutter is short

Also known as: kondensrende · dryprende · kondensbakke · afdrypningsrende · kølerende

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • The development is EXACT in both fall models: a prism develops without approximation, and the flat side panels in ‘horizontal top edge, bottom falls’ are proven flat. The entire uncertainty lies in the K-factor, and that belongs to the material, not the geometry. Always make a trial bend on the batch that will be used.
  • DIN 6935 covers ONLY structural steel. For stainless steel, aluminium and hot-dip galvanised steel the K-factor is an extrapolation — the machine's own bend table takes precedence over any formula.
  • The figure calculates NO flow capacity. Cross-sectional area, wetted perimeter and hydraulic radius R_h = A/P are pure geometry; roughness figures, Manning's number, minimum fall and design rainfall intensity are given in the drainage standard (DS 432) or in the manufacturer's instructions and are not invented here.
  • Hangers, support, anchoring and thermal expansion are NOT covered. A 6 m stainless-steel channel moves noticeably over a temperature range, and the support spacing depends on material thickness, content and profile.
  • Food and drinking-water hygiene is only covered as a CREVICE check: the figure can see that a lapped joint has a crevice, but it assesses neither surface roughness, weld quality, corner radii nor CIP coverage. That belongs under EN 1672-2 / EHEDG and the individual food business's own self-inspection.
  • A half-round gutter with a horizontal top edge and a falling bottom does not exist as a developable surface. If that combination is chosen, the figure calculates ‘the whole gutter falls’ and says so — it does not draw a development that is not true.
  • Pressure-bearing and closed channels (ducts under pressure) are outside the scope of this figure; they fall under PED and EN 13445 and must be sized accordingly.