Skip to content

Rafter template

Flat marking-out pattern for a rafter: birdsmouth at the ridge, plate cut and tail cut — with setting-out angles.

Exact flat patternNeutral fibre (mean dimension)11 dimensions6 presets
Toemrer · Tagdaekker …
Carpenter
beam · spær-skabelon …
beam · spær-skabelon · spærskabelon · spærlægte · opstregning · kløftsnit · remudskæring · fugleklo · birdsmouth · hanebånd · taghældning · sadeltag · haleskæring · eaves

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Neutral fibre (mean dimension). The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

11 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Roof shapetagtypeSadeltag (spær over halvdelen af spændvidden) · Pulttag / ensidet fald (spær over hele bredden)Sadeltag (spær over halvdelen af spændvidden)Duo-pitch roof: the rafter covers half the span (the other half is a mirrored rafter). Mono-pitch roof: one fall across the whole width.
The slope is entered ashaeldningsenhedGrader (°) · Rise per 12 (rise : run)Grader (°)Degrees, or rise per 12 (rise : run) as on a carpenter's square.
Roof pitchconditionaltaghaeldning5–60 ° · step size 145 °Slope of the roof plane from horizontal. The valley cut is set out at this angle from a right angle on the edge.
Rise per 12 (rise : run)conditionalrejsning_pr_121–24 : 12 · step size 0,512 : 12Rise over 12 horizontal units. 12 : 12 is 45°, 6 : 12 is 26.57°. θ = atan(rise / 12).
Span (building width)spaendvidde1.500–16.000 mm · step size 1007.000 mmThe building's external width. On a gable roof it is split in two; on a mono-pitch roof the whole width is one fall.
Rafter depth (timber height)spaerhoejde95–400 mm · step size 5220 mmThe deep dimension of the rafter timber, e.g. 220 in a 45×220. The birdsmouth may take at most 1/3 of it.
Overhang (horizontal)udhaeng0–1.500 mm · step size 10400 mmHorizontal distance from the wall edge out to the tail end. 0 = no roof overhang.
Strap width (seat contact)rem_bredde45–300 mm · step size 5100 mmThe wall plate's width = the bird's-mouth bearing width. Together with the pitch, it determines the depth of the wall-plate notch: d = plate width · sin θ, and it must be less than 1/3 of the rafter height.
Tail cut (end of the overhang)conditionalhaletypeLodret snit (plumb — parallelt med kippen, til lodret stern) · Vinkelret snit (savet vinkelret på spæret) · Vandret snit (level — til vandret undertag/sternbræt)Lodret snit (plumb — parallelt med kippen, til lodret stern)Vertical gives a vertical fascia face; horizontal a horizontal soffit; perpendicular a clean cross-section.

Advanced fields

2

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Rafter thickness (timber thickness)spaertykkelse38–100 mm · step size 145 mmThe out-of-plane thickness, e.g. 45 in a 45×220. It has no cuts — it is only used for the parts list.
Ridge board thicknesskip_tykkelse0–100 mm · step size 525 mmThe cleft cut meets the side of the ridge, not the centre of the building. The deduction on the horizontal run is half the thickness. 0 = the rafters meet without a ridge board.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Gable roof 45° (classic pitch)

7 m span, 45×220 rafters, 400 mm overhang — seat and plumb cuts both set out at 45°

Also known as: sadeltag · 45 grader · rejst tag · spidsloft · 12 på 12

Detached house roof 30°

9 m span, 45×195 rafters, 500 mm overhang — seat cut 30°, plumb cut 60°

Also known as: parcelhus · 30 grader · villatag · typehus · 7 på 12

Low-pitched roof 15°

6 m span, 45×220 rafters, horizontal tail cut — shallow pitch, seat cut 15° and plumb cut 75°

Also known as: lavt tag · flat roof · 15 grader · lavthældende · 3 på 12

Mono-pitch roof 18° (single fall)

4 m width, one fall across the whole width, 45×195 rafters, no ridge board

Also known as: pulttag · ensidet tag · shed · carport · halvtag

Steep roof 50° (church / spire-like)

5 m span, 45×245 rafters, narrow 80 mm wall plate so the birdsmouth stays below 1/3

Also known as: stejlt tag · 50 grader · spir · mansard · høj rejsning

Agricultural rafter 22° (large span)

12 m span, 45×295 rafters — over 6 m long, so it shows the splice warning

Also known as: agriculture · lade · maskinhus · stor spændvidde · gitterspær

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • The template draws GEOMETRY. Load capacity is NOT calculated: the rafter's bending and shear capacity, deflection, rafter spacing, the joints' capacity and the remaining cross-section above the rafter-tail cut belong under EN 1995-1-1 (Eurocode 5). A load-bearing roof structure must be designed and documented separately.
  • The rafter-tail cut's 1/3 limit is a CARPENTER'S RULE OF THUMB (workshop practice), not a sizing rule. The precise verification of the remaining cross-section and of the shear in the cut-out belongs under EN 1995 and depends on the load and the timber's strength class.
  • Wind load, snow load and STORM ANCHORING are not covered. Rafters must be tied down against uplift (ties, rafter shoes, strap) in accordance with EN 1991-1-3/1-4 and the specific location — the figure does not draw any fixings.
  • Collar ties, collar-tie ceilings, purlins, rafter struts, hips, dormers, valley gutters and hip rafters are not drawn. The template is one common rafter; hip, valley and skew rafters have their own, longer setting-out.
  • The material model is metallic, because the library is built for sheet metal. The weight key figure from the engine uses steel density and does NOT apply to a timber piece. The area, the lengths and the angles are correct — the mass is not.
  • The cutting dimensions are nominal centrelines. The saw kerf width (blade thickness) has not been deducted, and moisture movement, timber species and strength class (e.g. C24) have not been assessed.
  • The ridge deduction is half the ridge-board thickness and assumes that the cleft cut meets the side of the ridge board. A ridge-beam roof, a ridge without a board, and rafters that lap over each other at the ridge have different setting-out.

Onward from here