Edge profile — free bend profile in thin sheet
Wall copings, window sills, base flashings and gutter boxes: 2–8 pieces with bends between, driven by strip width and running metres.
How true is the flat pattern?
The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.
Dimensions are entered as: Outside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.
The vocabulary of bending
The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.
- Flat pattern (development)
- The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
- Flat length
- The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
- Bend allowance
- The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
- Bend deduction
- The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
- Outside setback
- The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
- Compensation value v to DIN 6935
- The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
- K-factor
- Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
- Neutral fibre
- The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
- Bend angle
- The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
- Inside bend radius
- The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
- Sheet thickness
- The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
- Fold line
- The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
- Test bend
- A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀
DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.
The dimensions you type
23 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Cross-section pieces (from front edge to back edge)segmenter | 4 fields per row · max. 8 rows | 3 rows (max. 8) | Read the profile as you draw it: the first section is the free front edge. The break in a row is the break BEFORE the section — the first row's break is therefore not used. |
| Substrate falldriverunderlagsfald | 0–45 ° · step size 0,5 | 0 ° | Corrects the bend angles so «vertical» is vertical in the world — not relative to the base. |
| Goods thicknesst | 0,4–4 mm · step size 0,05 | 0,7 mm | — |
| Sheet materialblikmateriale | As the context (the engine's material choice) · Titanium zinc (roofing zinc) · Aluminum · Hot-dip galvanised steel sheet · Black steel (painted) · Copper · Stainless 1.4301/1.4404 | As the context (the engine's material choice) | Controls thermal expansion, contact corrosion and the material's own working constraints. |
| Front edge (free edge, at the front)forkant | Skarp klippekant · Enkelt ombuk · Dobbelt ombuk · Rullet sikke · Stående fals / opkant | Enkelt ombuk | — |
| Front edge heightconditionalforkant_h | 3–60 mm · step size 1 | 15 mm | — |
| Rear edge (free edge, at the back)bagkant | Skarp klippekant · Enkelt ombuk · Dobbelt ombuk · Rullet sikke · Stående fals / opkant | Skarp klippekant | — |
| Rear edge heightconditionalbagkant_h | 3–60 mm · step size 1 | 15 mm | — |
| Strip width (from the supplier's data sheet)driverbaandbredde | 100–1.500 mm · step size 10 | 670 mm | Titanium zinc and copper are bought in strip. The width cannot be guessed — it is on the data sheet. |
| Part lengthemnelaengde | 100–6.000 mm · step size 50 | 2.000 mm | — |
| Run to be covereddriverstraekning_m | 0,5–500 m · step size 0,5 | 12 m | — |
| Overlap per jointoverlaeg | 0–200 mm · step size 5 | 30 mm | — |
| Joint along the runsamling | Overlæg, nittet (fast) · Overlæg, klemt (glidende) · Stående fals · Løst dilatationsstykke | Overlæg, klemt (glidende) | — |
| If the section is wider than the stripdeling | One piece (give error) · Split automatically with longitudinal seam | One piece (give error) | — |
| Mitre — plan angle of the corner (0 = straight cut)gering | 0–180 ° · step size 5 | 0 ° | — |
| Fall in the longitudinal directionfald_promille | 0–50 ‰ · step size 1 | 0 ‰ | — |
| The profile carries watervandfoerende | on / off | off | — |
| Working temperature when bendingarbejdstemperatur | -10–40 °C · step size 1 | 15 °C | Titanium zinc must not be worked below approx. 10 °C. |
| Material UPSTREAM in the drainageopstroems | Ingenting ovenfor · Copper · Bly · Titanium zinc · Aluminum · Stainless steel · Ubehandlet stål · Tagpap / bitumen | Ingenting ovenfor | Copper dripping onto zinc or aluminium eats through the sheet. |
Advanced fields
Hidden by default — they have a sensible default, and most parts do not need them.
| Dimension in mm | Interval | Standard | Explanation |
|---|---|---|---|
| Bend radius (0 = the material's minimum)bukkeradius | 0–20 mm · step size 0,1 | 0 mm | — |
| K-factor (0 = auto)k_faktor | 0–0,5 · step size 0,005 | 0 | The machine's own bend table beats any formula. 0 = the DIN 6935 suggestion. |
| Overlap in the longitudinal seamconditionaldel_overlaeg | 20–150 mm · step size 5 | 40 mm | — |
| Temperature range for thermal expansiontemperaturspaend | 40–120 K · step size 5 | 100 K | −20 → +80 °C surface temperature = 100 K. |
Ready-made presets
A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.
Wall coping (capping of a masonry cornice)
380 mm cover face with 3° fall, folded front and back — titanium zinc 0.7 mm
Also known as: murkrone · murafdækning · gesimsinddækning · murkappe · coping
Weather board (sill flashing)
200 mm board with 5° fall outwards, upstand behind the frame
Also known as: vandbræt · vandbrædt · sålbænk · sålbænksinddækning · vinduesbundstykke
Base flashing (plinth flashing)
Upstand behind render, horizontal cheek, drip nose at the front
Also known as: fodblik · sokkelblik · sokkelinddækning · fodinddækning
Eaves flashing (25° roof)
Rests on the substrate with a 25° fall — the bends become 115°, not 90°
Also known as: tagfodsblik · tagfodsbeslag · dryppladeblik · underbeslag · rendejernsblik
Edge trim (flat roof)
Upstand on the felt, cover face, facade front edge and drip nose tucked under
Also known as: kantafslutning · roof edge · kantprofil · sternkappe · tagkantprofil
Clamping rail
Vertical clamping face against wall with deflecting nose at 135°
Also known as: klemskinne · klemliste · afdækningsskinne · membranklemme
Verge flashing
Three free angles — facade side, top side and roof side
Also known as: vindskede · vindskedeinddækning · gavlinddækning · rakekappe
Window surround (reveal flashing)
Upstand in the seam, reveal face and front edge
Also known as: vinduesindfatning · lysningsinddækning · smigindfatning · karminddækning
Upstand profile (parapet)
Foot tab on the roof, high upstand and top edge outwards
Also known as: opkantprofil · attikaprofil · brystningsprofil · opkant
Ridge capping (30° roof)
Two flaps over the ridge — the bend is 60°, not 90°
Also known as: rygningskappe · rygningsinddækning · tipping · kipkappe · rygningsblik
Valley gutter — cross-section (25° roof surfaces)
The kink is 2 × 17.388° = 34.775°, not 180 − 2·25 = 130°
Also known as: skotrende · skotrendeblik · valley · kilrende · renderyg
Box gutter (concealed gutter)
U-shaped box: outer cheek, bottom, back cheek and back tab
Also known as: rendekasse · skjult rende · kasserende · indbygget tagrende · box gutter
Drip nose (drip edge)
Fixing tab, front edge and 45° deflecting nose
Also known as: vandnæse · drypnæse · drypkant · dryplist · afdrypningsprofil
Reservation
Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.
- The development is EXACT — a chain has no geometric approximation. The entire uncertainty lies in the K-factor, and that belongs to the material, not the geometry. Always make a trial bend on the batch that will be used.
- DIN 6935 covers ONLY structural steel. For titanium zinc, copper, aluminium and stainless steel the K-factor is an extrapolation — the machine's own bend table takes precedence over any formula.
- The strip width is an INPUT from the supplier's data sheet. The tool never suggests a commercial width; titanium zinc and copper are supplied in fixed strip widths that must be looked up.
- The expansion spacing of 8–15 m applies to titanium zinc and is guidance-only workshop practice. It depends on profile, fixing and exposure and must be verified against the supplier's installation instructions.
- Fixing, wind load and anchoring are NOT covered. An edge trim on a flat roof is a wind-exposed building component and must be sized in accordance with EN 1991-1-4 and the roof covering's own instructions.
- The mitre cut is supplied as a setting-out table and a 1:1 detail, not in the cutting file: the blank from the chain development is right-angled.
- Fire requirements, acoustics and the flashing's tightness against the rest of the building envelope are outside the scope of this figure.