Cable tray

U-shaped folded sheet-metal tray — base and two upturned sides, optionally with a turned flange and perforated base, in a given length.

Exact flat patternInside dimensions16 dimensions9 presets
Elektriker · Automatiktekniker …
Electrician
cable tray · kabelrende …
cable tray · kabelrende · føringsvej · installationsbakke · lysbakke · pladebakke · kabelkanal-åben · perforeret bakke · cable tray · U-bakke · elbakke · svagstrømsbakke

How true is the flat pattern?

The surface is developable and the flat pattern is solved in closed form. Cut the part to the drawing and it fits — the whole uncertainty sits in the K-factor, which belongs to the material and the machine, not to the geometry.

Dimensions are entered as: Inside dimensions. The flat pattern itself is always computed on the neutral fibre — at Ø800 in 3 mm sheet the difference between the inside and the outside dimension is 18.8 mm of developed width, and then the seam does not meet.

The vocabulary of bending

The words and formulas the trade uses for a flat pattern. The symbols are the same throughout Discebo: α is the bend angle in degrees, R the inside bend radius, t the sheet thickness and K the K-factor — all in millimetres.

Flat pattern (development)
The part's surface laid out flat as one continuous cutting outline — the way the sheet looks BEFORE it is bent or rolled. Only a developable surface can be unfolded exactly; a doubly curved surface cannot be laid flat without stretching the material.
Flat length
The flat length the part must be cut to so the dimensions come out right once it is bent. It is either the sum of the outside dimensions minus the bend deductions, or the sum of the flat legs plus the bend allowances — both routes must give the same number.L = Σ(udvendige mål) − Σ(BD) = Σ(flade ben) + Σ(BA)
Bend allowance
The length of material that sits in the bend itself, measured along the neutral fibre. The bend allowance is always positive and is added to the flat legs.BA = (π/180) · α · (R + K · t)
Bend deduction
The amount subtracted from the sum of the outside dimensions, because the two outside dimensions between them count the corner twice. Here the bend deduction is taken as POSITIVE and subtracted; DIN 6935 writes the same quantity as the compensation value v with the opposite sign.BD = 2 · OSSB − BA
Outside setback
The distance from the theoretical outside corner point in to where the bend starts. Above 90°, tan(α/2) is clamped to at most 1 per DIN 6935, so the number does not explode towards 180°.OSSB = tan(α/2) · (R + t)
Compensation value v to DIN 6935
The standard's own way of writing the same corner loss: the flat length is a + b + v, where v is negative. Our bend deduction is therefore the same quantity with the opposite sign — never flip one without the other.L = a + b + v ⇒ v = −BD
K-factor
Where the neutral fibre sits in the sheet, given as a fraction of the sheet thickness. DIN 6935 writes the correction factor k, which applies to the neutral line in the form (R + t·k/2); the American CAD convention writes (R + K·t), so K = k/2.k = 0,65 + 0,5 · log₁₀(R/t), k ≤ 1,0 ⇒ K = k/2
Neutral fibre
The layer in the sheet that is neither stretched nor compressed when the part is bent. The flat pattern is always computed on the neutral fibre — which is why it matters whether the drawing's dimensions are inside or outside.
Bend angle
The angle the material is turned through, not the angle between the legs. The bend angle is 180° minus the included angle, so a square corner is 90° and a seam fold is 180°.α = 180° − åbningsvinklen
Inside bend radius
The radius on the inside of the bend. It is set by the tooling and the material, not by the drawing — too small a radius cracks the part in the outer fibre.
Sheet thickness
The thickness of the material. It enters every single bend allowance, so sheet delivered 0.2 mm thicker than ordered shifts the flat length at every bend.
Fold line
The line on the flat pattern where the part is to be bent. It is drawn but never cut through — in a laser file it therefore sits on its own layer.
Test bend
A strip of known raw length, bent in the material and the tooling that production will use. Measure the two outside legs afterwards and the bend deduction and K-factor can be worked back. The machine's own measured bend table beats any table.BD_målt = (A + B) − L₀

DIN 6935 covers only cold bending of flat products in structural steel. Stainless, aluminium, copper, brass and titanium zinc are not included — there the formulas are an extrapolation, and a test bend in the actual material settles it.

The dimensions you type

16 fields. The starting values belong to the figure itself — they live in one place in the code, so the tool, the share link and the smoke test can never disagree about what «default» means.

Dimension in mmIntervalStandardExplanation
Top edge of the sideskanttypeSkarp topkant (afgratet) · Sikkerhedssik (ombukket topkant, 90°) · Retvendt flange (opadvendt kant-ombuk)Skarp topkant (afgratet)A sharp edge is simply deburred; the bead is bent 90° over on the free edge; the upright flange is an upward edge fold that stiffens the top and protects the cables.
Inside width (bottom)bredde_bund50–1.000 mm · step size 10200 mmThe free cable space across. The chain is calculated on the external dimension width + 2·t.
Inside side heightsidehoejde25–200 mm · step size 560 mmThe free cable space in height, from the inside of the bottom to the top edge.
Tray lengthlaengde200–6.000 mm · step size 503.000 mmStandard sections are often 3,000 mm. The blank is the cross-profile's development × this length.
Hem/flange heightconditionalkant_hoejde6–40 mm · step size 115 mmThe hem's fold-over or the flange's inside height. The upright flange stiffens the top edge.
Perforated bottomperforeringon / offoffHoles/slots in the bottom for ventilation, cable ties and drainage. They are placed in the flat field of the bottom.
Hole shapeconditionalperf_formRunde huller · Langhuller (slidser langs bakken)Langhuller (slidser langs bakken)—
Hole diameter / slot widthconditionalperf_diameter3–40 mm · step size 0,57 mmRound holes: the diameter. Slotted holes: the width of the slot.
Slot lengthconditionalperf_slids6–80 mm · step size 125 mmLength of the slotted hole along the tray. Must be at least equal to the slot width.
Rows across the bottomconditionalperf_raekker1–12 stk. · step size 13 stk.Number of hole rows distributed evenly across the bottom's flat width, symmetrical about the centre.
c/c along the trayconditionalperf_cc8–200 mm · step size 138 mmHole spacing along the length of the tray. Standard perforations often use a 38 mm pitch.
Goods thicknessgodstykkelse0,7–3 mm · step size 0,051 mmTray sheet. The thickness the load REQUIRES is given in EN 61537 — it is an input here.
MaterialmaterialevalgSom værkstedets (fra opsætningen) · Varmforzinket stålplade (DX51D+Z) · Stainless steel · AluminumSom værkstedets (fra opsætningen)—

Advanced fields

3

Hidden by default — they have a sensible default, and most parts do not need them.

Dimension in mmIntervalStandardExplanation
Edge distanceconditionalperf_kant5–100 mm · step size 120 mmFree edge round the perforation, towards both bend lines and tray ends. At least 2.5·t + R from a bend.
Inside bend radiusbukkeradius0–5 mm · step size 0,10 mm0 = R is set equal to the material thickness, which air bending gives by itself. The machine's bend table beats any formula.
Coil/sheet widthcoilbredde600–2.000 mm · step size 501.250 mmTray sheet is roll-formed/cut from strip. The blank must fit within the width in at least one of its two directions.

Ready-made presets

A preset sets every dimension at once. The name is often the word the part goes by in the workshop — the library's search knows them all.

Lighting tray 100 × 60 (perforated)

100 mm wide, 60 mm high, slotted perforated bottom — 1.0 mm hot-dip galvanised

Also known as: lysbakke · kabelbakke lille · 100x60 · installationsbakke · perforeret bakke

Perforated tray 200 × 60

Classic 200 × 60 installation tray — three rows of slotted holes, upright flange, 1.0 mm

Also known as: 200x60 · kabelbakke standard · perforeret bakke · installationsbakke · gitterløs bakke

Heavy-duty tray 400 × 110

Wide heavy-duty tray 400 × 110 with straight flange and 1.5 mm sheet — perforated bottom

Also known as: 400x110 · kraftig bakke · bæreevnebakke · hovedføringsvej · bred kabelbakke

Continuous bottom 150 × 50 (EMC shield)

Unperforated bottom for noise-sensitive installations — solid sheet gives better screening

Also known as: ubrudt bakke · emc bakke · tæt bund · skærmet bakke · 150x50

Stainless tray 200 × 60

Stainless 1.5 mm for damp and corrosive environments — upright flange, unbroken bottom

Also known as: rustfri kabelbakke · syrefast bakke · 1.4301 bakke · korrosionsfast bakke · vådrumsbakke

Distribution tray 600 × 100

Wide main cable route 600 × 100, 2.0 mm — the transverse blank of approx. 806 mm must fit the coil width

Also known as: 600x100 · fordelingsbakke · hovedvej · bred føringsvej · storbakke

Data cable tray 100 × 50 (finely perforated)

Narrow tray for low-voltage/data with round holes and hem — 1.0 mm

Also known as: datakabelbakke · svagstrømsbakke · netværksbakke · 100x50 · signalbakke

Aluminium light tray 200 × 60

Light, corrosion-resistant aluminium 1.5 mm — 2.70 against steel's 7.85 kg/dm³, upright flange

Also known as: aluminiumbakke · alubakke · letbakke · korrosionsfast bakke · offshore bakke

Short fitting tray 200 × 60 (500 mm)

Short fitting piece of 500 mm — same section, cut to length on site

Also known as: pasbakke · passtykke · kort bakke · tilpasningsstykke · mellembakke

Reservation

Read them before the part is cut. They are here because they cannot be calculated away — not as legal text, but as craft.

  • Load capacity and span between supports are NOT covered. How far a tray may span with a given cable load depends on width, material thickness and support type and is classified by type testing to EN 61537 — a development is not a load-capacity document.
  • Earthing and equipotential bonding are NOT covered. A metal cable tray is an extraneous conductive part and must be earthed in accordance with DS/HD 60364-5-54; each section joint must have documented conductivity.
  • The figure is not a certified support system. EN 61537 classifies the tray's load capacity, safety factor and mounting spacing — they are an input here, not an outcome of the pattern.
  • Fire class and function preservation (e.g. E30/E90) are NOT covered. Cable installations with a requirement for functional integrity during fire must be executed as a certified system in accordance with EN 50577 / DIN 4102-12.
  • The perforation's effect on the load capacity has not been calculated. Holes reduce the cross-section's moment of inertia; the permissible load for a perforated tray is given in the tray's own type test.
  • Fixing, hangers, expansion and load distribution are not covered. The spacing between hangers and the choice of supports belong to the routing project.
  • Springback is not compensated for. The development is calculated on the desired 90° bends; how much must be over-bent depends on material, thickness and V-opening and belongs on the machine.
  • Only the geometry is traceable. Material thickness, hole pattern and material are input; they must match a real tray range — the tool invents neither load capacity nor hole pattern.